1answer

Keep getting a manifold overheating beep. even after light use. after 1/2 hour of starting machine. We clean the radiator before each use and air cleaner is good to go

Check the exhaust silencer for blockage, hold your hand at the end of the pipe and feel if there is a fair amount of pressure while it is running, if not, replace
8/18/2015 6:32:28 PM • John Deere 310sj... • Answered on Aug 18, 2015
0helpful
1answer

How to remove the bolts on the starter John Deere Gator 620i

This is what I did to remove starter on 620i xuv gator. Remove starter solenoid and use extension 3/8 drive with universal joint to remove top bolt or remove front half of plastic shroud over drive belt assy , drill hole into cover in line with top starter bolt, insert extension with socket onto top starter bolt. Be sure to cover drilled hole with suitable material.
8/14/2015 7:14:15 PM • John Toys • Answered on Aug 14, 2015
0helpful
1answer

Keeps going into neutral popping in an out of gear

Hi Frank: I'd start by checking the linkage for excessive wear. There will probably be a cam or spring loaded device that keeps the shifter linkage in the correct position. Sometimes an accumulation of contaminated grease/dirt can prevent the proper function.
7/1/2015 4:24:50 PM • John Deere 310sj... • Answered on Jul 01, 2015
0helpful
2answers

Cannot open my Sentry Safe S3460

Contact a local locksmith
5/4/2015 8:33:13 PM • John Sentry 1.2... • Answered on May 04, 2015
0helpful
1answer

NOPOWER TO FRIG. ALL THREE 12V GAS ELECTRIC. VERY LOW BATTERY IS IT THE PROBLEM OR CAN I LOOK FOR SOMETHING OTHER THAN LOW VOLTAGE. CAR RUNNING NO 12V. THIS IS IN MY CARAVAN. JOHN

Fridge not starting? CLICKING? FIRST ALWAYSCHECK FORpower at the outlet,checkfor 120 volts. MAY HAVE A BAD START RELAY OR CAPACITOR ON THE COMPRESSOR , CAN BUY A INEXSPENSIVE 3 IN 1 HARDSTART KIT AND BY PASS THEM , NOT THAT HARD TO DO, COMES WITH INSTRUCTIONS> BY THE WAY DO U HEAR ANY CLICKING SOUNDS FROM COMPRESSOR? BUT U MAY ALSO WANT TO CHECK UR COLD CONTROL THERMOSTAT IF IT GOES BAD U MAY GET A NON START ALSO HAVE IT CHECKED FOR PROPER VOLTAGE AND OHMS RESISTANCE WHEN IN THE ON POSITION A BAD DEFROST TIMER CAN SHUT DOWN COMPRESSOR HAVE IT CHECKED WITH MULTI METER. to check the defrost timer, u can get by and test manually by placing a small screw driver into the tiny slot or hole underneath the timer and turn slowly clockwise till u hear 1 click. this will engage ur defrost cycle in about 15 minutes u should be able to come back and feel the heat in freezer as it melts the ice providing ur terminator is not bad? Another way to test it is with a multi meter. Remove timer it from fridge and you will see 4 prongs numbered 2,1,4,3 in that order. Place ur meter prong on prong 1 & 3 (if your fridge has a capacitor wired in series with the windings, then u check for micro fares rather than OHMS) If u cannot confirm this test, still try the next. Take ur meter prong and connect to prong 1 & 4, it should read resistance or ohms ( closed) now remove prongs and place on prong 1 & 2, this should now read infinity or open (no ohms) now take a small screwdriver place it in the tiny hole or slot under the timer. Turn it clockwise slowly till u hear 1 click. Now ur 1& 2 should read closed ( showing ohms or resistance) now place meter prongs on 1 & 4 and you it should now show open ( or no resistance - no ohms) this is how u know ur timer is good, Remember when testing for ohms ADJUST meter to use a high ohms rating in the thousands as the resistance is very high in OHMS. And adjusting to low ohms rating may give a false reading or not show the proper resistance.. AT TIMES YOU MAY HEAR THE COMPRESSOR CLICK OFF AND ON OVER AND OVER. Signs of a bad start relay or capacitor. Check with an OHMS meter for continuity (ohms) and voltage, capacitor can be checked for Microfares. To check ur compressor with multi meter: Disconnect and remove the relay and capacitor from compressor, somes located next to compressor in a casing. You wills see 3 prongs coming out of compressor. 1 goes to ur srtart winding, 1 goes to ur run winding and the center goes to ur ground. Place ur meter connector or prong on the start prong and the other on the ground (center prong) take note of the reading in OHMS for example 5 ohms. Next place meter prong on run prong and the center ground prong agin. Take note of the reading in OHMS. Example 4 ohms Next place meter prong on the start prong and the other on the run prong, now take note of the reading example 9 ohms. Now match the total of this ohms test with the total of ur two separate test. 9 ohms, if they match ur ok give or take 5 percent plus or minus. One more test to make to test of there is a short in compressor attach meter prong to ground prong and rub the other end of meter prong to metal ( scrape the metal clean of paint and test on metal surface not painted surface. If it shows continuity or ohms , u have a short in ur compressor. It should show infinity
4/29/2015 7:36:08 AM • John... • Answered on Apr 29, 2015
0helpful
2answers

Comment: Hi. I have a TC. PC42C2 Panosonic TV which seem to get warm or hot by the switch and stops working then works again when it cools off. The on off switch has been wonky for a while. Now it har

Ask a tech to replace the switch. don't try this yourself, unless you have the needed skills.
3/24/2015 1:37:02 AM • John... • Answered on Mar 24, 2015
0helpful
1answer

The steering on a 648G john deere logging skidder will not steer

bad proportioning valve If you need further help, I’m available over the phone at https://www.6ya.com/expert/michael_00678fd4800d19c5
3/2/2015 10:51:17 PM • John Ertl 132... • Answered on Mar 02, 2015
0helpful
1answer

How do i stop the engine running at a fast idle

Assuming it is a completely mechanical system with no electrical or electronic control there is no actual fast idle facility unless it is provided by a Waxstat cable device fitted into the cooling system. I think what you mean is the engine idle speed is too fast rather than it is running at "fast idle" which is a term used for a raised idle speed when an engine is cold and decreases as the engine warms until at normal operating temperature the idle speed should be normal. On an old diesel engine it is the Waxstat device if fitted that provides this facility or a hand operated throttle. Very old cars and trucks had hand throttles for fast idle but later this function was provided by the choke or strangler mechanism. Some luxury cars had an electrical device fitted but the fast idle of modern engines is invariably provided by electronics. I expect you need to adjust the throttle stop screw of the injection pump. This is at the lever where the throttle linkage connects to the pump and there is generally two stop screws fitted that limit the travel of the lever. One screw limits the maximum travel of the lever and therefore the maximum engine speed and this is generally set during manufacture or remanufacture and sealed to prevent tampering. The other screw is the idle screw which the lever is pulled against by a spring when at rest. Before adjustment it is necessary to ensure the throttle linkage is not maladjusted and preventing the lever contacting the stop. Disconnecting the linkage until the idle speed has been adjusted will ensure this and then slacken the stop screw locknut, start the engine and turn the screw in or out as applicable until the desired idle speed is achieved, allow the engine to warm up and make further adjustment if necessary and tighten the locknut and reconnect the throttle linkage. Do not adjust any pump screw except the idle screw. Good luck!
3/1/2015 1:23:40 PM • John DEERE... • Answered on Mar 01, 2015
0helpful
1answer

I need a wiring schematic for a John Deere 4430 with rops

Try this site to get your manual. http://www.manualsonline.com
1/7/2015 4:45:34 AM • John Deere 4000... • Answered on Jan 07, 2015
0helpful
1answer

Manual for wiring diagram for John Deere 4430 - schematic

Try this site to get your manual. http://www.manualsonline.com
1/7/2015 4:43:14 AM • John Deere 4000... • Answered on Jan 07, 2015
0helpful
1answer

Dishwasher not drying, everything wet and cold?

That's what to check first.
9/6/2014 9:34:20 PM • John Lewis... • Answered on Sep 06, 2014
0answers
0answers
0answers
Not finding what you are looking for?

Ask a Question

Usually answered in minutes!

Top John Experts

Brad Brown

Level 3 Expert

19187 Answers

john h

Level 3 Expert

29494 Answers

ADMIN Andrew
ADMIN Andrew

Level 3 Expert

66835 Answers

Are you a John Expert? Answer questions, earn points and help others

Answer questions

Manuals & User Guides

Loading...