Jacuzzi Pool & Spa - Popular Questions, Answers, Tips & Manuals
Gfci overheat call for service
If you have any clamp on amperage meters, you need to see what the amperage draw on the circuit is when it is running. This will tell you if something is wrong with the pump circuit. It could be anything from a bad capacitor to an impeller obstruction.
I have a Leisure Bay 24 ft above ground pool
probably a "O" ring as the seal
if the pump is doing what it is supposed to be doing and everything is normal. I would not stress about air under the cover as water contains air in suspension ( how fish get their oxygen to live) and from the turbulent action of the pump impeller , some of that air will be released and collected at the highest point of the flow line
Need manufacturer's support specifications
This is not that easy to take care of.
1. The building code version and requirements can be different depending on your location.
2. No manufacturer posts that information for that reason.
3. It will require an engineering study and that is required by most building codes.
4. Supporting structure may be only part of the issue, gates, alarms etc are required by some jurisdictions.
Remember that water weighs 8 lbs to the gallon and a hottub can hold a lot of water.
PUMPS WONT TURN OFF
The pushbutton is electrically isolated from the actual on/off switch for obvious safety reasons. The mechanical coupling mechanism could be broken as could be the switch itself. It is not intended to be repaired by the homeowner but you could try if you are handy. Before investigating, turn offo the circuit breaker to the pump. Likely that is how you had to turn it off anyway.
If this is beyond you, call a plumber. Unfortunately, there are very few options.
Not finding what you are looking for?