I have a kubota av6500 generator runs great but the output voltage at the 120volt receptacle is 163 volts and at the 120 voltage 20amp plug is 38volts what could be the problem thanks

There could be several reasons why the output voltage of your generator is not within the normal range. Here are a few things you can check:
  1. Make sure the generator is properly grounded.
  2. Check the voltage regulator. It could be malfunctioning and causing the high voltage output.
  3. Check for loose or damaged wiring. Any issues with the wiring could cause the voltage to be incorrect.
  4. Check the engine speed. If the engine speed is too high, it could cause the voltage to be higher than normal.
  5. Check the load on the generator. If the load is too low, it could cause the voltage to be higher than normal.
If you are unable to identify and fix the problem, it is recommended to have a professional technician diagnose and repair the generator.
12/14/2022 3:52:56 PM • Electrical... • 75 views • 0 helpful votes
0helpful
1answer

Carrier comfort pro 6100 apu

If the Carrier Comfort Pro 6100 APU is not producing AC voltage, it will shut off as it is designed to do so to protect the system. This is because the APU needs to have a stable voltage output to run properly, and if there is no voltage, the system will shut down. Regarding the circuit breakers, it's possible that they may be faulty and need to be replaced. You can test the breakers with a multimeter to determine if they are functioning properly. If they are not, you will need to replace them. However, there could be other issues causing the lack of voltage from the generator. It's possible that the generator itself is faulty or that there is an issue with the voltage regulator. A professional technician with experience working on APUs would be best suited to diagnose and repair the issue.
10/27/2022 12:08:15 AM • Electrical... • 241 views • 0 helpful votes
0helpful
3answers

No power coming out of my generator

Check AC reset button has not tripped.
12_3_2022_4_19_02_pm.jpg
12/3/2022 2:47:51 AM • Electrical... • 70 views • 0 helpful votes
0helpful
1answer

What does it mean when I test for voltage with my wiggy and the black and white in the middle lights up and the tester isn't showing any voltage?

What make/model? Does it vibrate or hum?It likely means something just under a 100VAC. Measure with a DMM. Measure in both AC and DC modes. Check frequency as well.Comment for further assistance.
12/17/2022 5:03:08 AM • Electrical... • 49 views • 0 helpful votes
0helpful
2answers

My Comfort Zone cz260er is wired and there is juice to everything but no light when powered on and on/ off button does nothing.

Hi, please ensure that you've got the recommend voltage and current going to your device based on the product manual. If it's getting hot but not turning on, you could be doing everything correctly but the device is faulty. I would suggest next using the troubleshooting section of your manual before calling the manufacturer to ask for a possible trade-in of the device. Thank you.
11/10/2022 10:09:17 PM • Electrical... • 111 views • 0 helpful votes
0helpful
1answer

Power switch discontinued

If you received the single pole switch as an alternative from a Miller dealer/service then it should have came with instructions.

Likely it can be done but the unit will no longer have a complete de-energized state, just merely open circuit which means it will function electrically but not necessarily meet safety standards which may or may not be a problem in your service environment.

I'd suggest a DPST such as;

https://www.amazon.com/Miller-116830-Switch-Rocker-250Vac/dp/B004HEDK1G

However, it may or may not be the same physical dimensions. Contact seller.
12/31/2022 5:11:18 AM • Electrical... • 31 views • 0 helpful votes
0helpful
3answers

How to determine which 2-way electrical switch is bad?

you forgot to say home light switches, or if is car no car told nor that the switch does. (or has a dimmer) where you, home or car. what are you touching, be specific thanks
12/2/2022 2:24:34 PM • Electrical... • 54 views • 0 helpful votes
0helpful
1answer

20 RESA failed to exercise for 20 mins, only ran for 2 mins

Problem with this, guessing that normally the power generated is somehow dumped when there is no real load applied. Digital voltage regulator with ±1.5% no-load to full-load RMS regulation. https://www.google.com/search?q=20+RESA%2C+testing+with+no+load ..
12/17/2022 5:37:40 PM • Electrical... • 38 views • 0 helpful votes
0helpful
1answer

My generator Ryobi rg 2700 kills lights and main plugs in my house help please

Hi, Please work with an electrician to ensure that your house is setup properly to use the type of generator that you've listed. Thank you.
9/27/2022 4:41:45 PM • Electrical... • 262 views • 0 helpful votes
0helpful
1answer

Where can I get a replacement Ann YIH AM-06 motor?

See if either of these are anywhere close... you may need to be creative with mounting or shaft adaption but both are ccw 6rpm 120vac.https://www.amazon.com/uxcell-Synchronous-100-127V-5-6RPM-50-60Hz/dp/B07Y6LQ9S7https://www.ebay.com/itm/284538092633https://www.harfington.com/products/p-1030989?currency=USD&variant=42245771526393&utm_medium=cpc&utm_source=google&utm_campaign=Google%20Shopping&utm_source=google&utm_medium=cpc&utm_campaign=1008-pmax-us-powerele8&utm_term=1008-pmax-us-powerele8&utm_content=ywh&gclid=Cj0KCQjw4omaBhDqARIsADXULuXL5kHwCBY5CH_b_K3E3orB4olt3JqZjfMx9Mp8mnp4ysJ-plzqOGoaAshNEALw_wcB
10/9/2022 8:48:18 PM • Electrical... • 172 views • 0 helpful votes
0helpful
1answer

Troy Bilt 3550 5250 Watts Generator model# 01924. How do I replace a Fuel Shut-Off Valve and grommet on it?

Question edited for clarity. Question moved from Cars and Trucks to Generators. Hi Joe Good to see you. There is a picture of it here. I would put some Vaseline on the spigot and support the grommet at the back, push and turn at the same time. This is a video here that may help https://www.google.com/search?q=Troy+Bilt+3550+5250+Watts+Generator%2C+replace+fuel+valve ..
11/5/2022 11:32:31 PM • Electrical... • 77 views • 0 helpful votes
0helpful
1answer

Some light stays off when I open the door on my 2009 GMC Sierra

Interior lighting is handled by the BCM. Each door has a controller that communicates the state (open/closed) with the BCM. If the CEL is on, read OBD codes for possible BCM or door controller faults.
11/27/2022 7:31:16 PM • Electrical... • 43 views • 0 helpful votes
0helpful
1answer
0helpful
1answer

Need set of ignition keys for 19hp powermate model0545305.03 19G412

Suggest you contact Powermate.

https://www.powermate.com/support/home
12/12/2022 3:43:27 AM • Electrical... • 25 views • 0 helpful votes
0helpful
1answer

I have a dimmer with 2 black and 1 green, the house has 3 black , 3 white 3 green and 1 red how do I wire

In the link, diagrams and videos. HOWEVER, some of the wiring colors vary by country. I am British, so red live, black neutral and green earth. Black line, white neutral, red load and bare wire ground in north America https://www.google.com/search?q=dimmer+with+2+black+and+1+green%2C+the+house+has+3+black+%2C+3+white+3+green+and+1+red ..
11/8/2022 7:48:56 PM • Electrical... • 48 views • 0 helpful votes
0helpful
1answer

Can this controller be replaced with a controller thats not nema 4

Whether or not a NEMA 4 controller can be replaced with a controller that is not NEMA 4 depends on the specific application. NEMA 4 controllers are designed to withstand water and dust ingress, so they are often used in outdoor or harsh environments. If the controller is being used in an environment where it is exposed to water or dust, then it is important to replace it with a NEMA 4 controller. Overall, it is important to consult with a qualified electrician before replacing a NEMA 4 controller with a controller that is not NEMA 4. The electrician can assess the specific application and recommend the best controller for the job. If you want to look for a controller, you can visit: https://www.chipsmall.com/bigcategory/industrial-automation-and-controls.html to search for the controller you want.
10/10/2022 3:32:24 PM • Electrical... • 95 views • 0 helpful votes
0helpful
1answer

Started up power back 5250 and after 30 seconds started smoking out of winding vents

bad news that gen copper windings smoke is load shorted? or no load smoke.? no told connected what. gen?>>>> to what? I bet the maker has no part for sale, china imports mostly do not. off to harbor Fright(pun) you go.
11/16/2022 1:16:46 PM • Electrical... • 33 views • 0 helpful votes
0helpful
1answer

How many gallons of gas will a duro power 3500 watt generator hold

4.0 gallon if fuel tank is full.
12/3/2022 12:37:09 AM • Electrical... • 24 views • 0 helpful votes
Not finding what you are looking for?
GMC Logo

26 questions posted

Ask a Question

Usually answered in minutes!

Top GMC Electrical Supplies Experts

Brad Brown

Level 3 Expert

19187 Answers

john h

Level 3 Expert

29494 Answers

ADMIN Andrew
ADMIN Andrew

Level 3 Expert

66963 Answers

Are you a GMC Electrical Supply Expert? Answer questions, earn points and help others

Answer questions

Manuals & User Guides

Loading...