Predator 3500 AC Generator. Error 5 code. What does it mean?

Error code 5 on a Predator 3500 AC generator typically indicates an issue with the generator's fuel system. The error code may be caused by a problem with the fuel pump, fuel filter, fuel hose, or fuel tank. It could also be caused by a problem with the generator's carburetor or fuel injection system. To troubleshoot the error code 5 on your Predator 3500 generator, you can try the following steps:
  1. Check the fuel level in the tank. If the tank is empty or low on fuel, fill it up and see if the error code goes away.
  2. Inspect the fuel hose for any cracks, kinks, or leaks. Make sure the hose is properly connected to the fuel tank and fuel pump.
  3. Replace the fuel filter if it is clogged or damaged.
  4. Check the fuel pump for any issues. The fuel pump may be malfunctioning or damaged, or it may not be getting enough power.
  5. Check the carburetor or fuel injection system for any issues. The carburetor or fuel injectors may be clogged or malfunctioning, or there may be a problem with the fuel pressure.
If these steps do not fix the error code 5 on your Predator 3500 generator, it may be necessary to consult a mechanic or the manufacturer for further assistance.
1/3/2023 4:43:57 AM • Electrical... • 602 views • 0 helpful votes
0helpful
1answer

How do I throttle down Black Max generator?

You adjust the idle speed. The manual is vague, but there should be an adjuster with a visible spring on the carburetor body or throttle linkage. https://www.manualslib.com/manual/1189243/Black-Max-Bm903600.html?page=22&term=speed&selected=2#manual The idle speed is dependent on the engine make ..
2/3/2023 10:48:55 PM • Electrical... • 236 views • 0 helpful votes
1helpful
2answers

What is the valve clearance on a ryobi rg 7900k generator?

0.15mm +-.02 intake. (.006 in)
0.20mm +-.02 exhaust (.008 in)

engine cold
1/14/2023 8:23:36 PM • Electrical... • 358 views • 1 helpful votes
0helpful
1answer

I need to know what wires go were on a Kraft 6000 watt generator please?

Question edited into written English, 'no' and 'know' are two different words. And did you mean King Craft? There is none called 'Kraft'. Also model numbers are need in such questions, 6000 watt is just the output. some help in the link, but no idea if it is relevant to what you have. https://www.google.com/search?q=kraft+6000+watt+generator+wiring+diagram The correct search query for this is; make model wiring diagram nothing else..
3/10/2023 8:47:48 PM • Electrical... • 66 views • 0 helpful votes
0helpful
2answers

My ryobi rg-2600i does not have a reset button. How do i reset the overload

  • Unplug any appliances or devices that are connected to the generator.
  • Turn off the fuel valve, and let the generator cool down for at least 10 minutes.
  • Check the oil level in the generator, and add more oil if necessary.
  • Check the air filter and clean or replace it if it is dirty.
  • Turn the fuel valve back on and start the generator.
  • Check the spark plug to make sure it is in good condition and properly seated. If it is dirty or damaged, clean or replace it.
  • Check the fuel line to make sure it is not clogged or damaged. If it is, replace it.
  • Check the fuel filter to make sure it is not clogged. If it is, clean or replace it.
  • Check the carburetor to make sure it is clean and functioning properly. If it is dirty or damaged, clean or rebuild it.
  • Check the voltage regulator to make sure it is functioning properly. If it is damaged, replace it.
  • Check all of the connections on the generator to make sure they are secure and not damaged.
  • Check the generator's fuel tank to make sure it is full and that the fuel is fresh. If the fuel is old, it may have gone bad and will not burn properly.
  • Check the generator's battery to make sure it is charged and functioning properly. If the battery is dead or damaged, the generator may not start.
  • Check the engine for any visible signs of damage or wear. If you see any cracks, leaks, or other issues, the engine may need to be repaired or replaced.
  • I know it is a basic checklist... I just hope that I might have thought of something that you did not? two minds are better than one... sometimes.
1/8/2023 9:59:07 AM • Electrical... • 311 views • 0 helpful votes
0helpful
1answer

Model 1001 311 060 Motion security light

Try setting DUAL BRIGHT to OFF.

Be sure daylight sensor is clear.

Try putting unit into test mode and it should be full ON or full OFF. If not, then likely unit is bad.
3/29/2023 7:45:22 PM • Electrical... • 39 views • 0 helpful votes
0helpful
1answer

I am replacing an old dimmer with a new one.

Easiest Way to Replace a 3-Way Switch If you're simply swapping an old 3-way switch for a new one, use this simple trick to get the wiring right: Before disconnecting any wires on the old switch, find the wire attached to the common screw terminal and label it with a piece of tape. Then, you can disconnect all three wires from the switch, as well as the ground wire. Because the other two wires (the travelers) are interchangeable, it doesn't matter which of the traveler screws you attach them to-there's no need to label them.
3/20/2023 2:38:15 PM • Electrical... • 47 views • 0 helpful votes
0helpful
1answer

Why is my SaniFlo Saniaccess 2 tripping my GFCI constantly?

GFCI or RCD tripping is either moisture has entered the motor body or there is a wiring fault. Neither of which would I consider a warranty issue especially noting the age. Call an electrician to diagnose the fault first then take it from there.
2/19/2023 2:31:34 PM • Electrical... • 67 views • 0 helpful votes
0helpful
1answer

Kawasaki GA1400A Generator. It starts fine, 12 volts okay, but no 230 volts.

Question edited for clarity. Question moved from Motorcycles to Generators category. Some help in the link, but not as much as I would like https://www.google.com/search?q=Kawasaki+GA1400A+no+230+volts+output ..
1/8/2023 12:06:29 PM • Electrical... • 123 views • 0 helpful votes
0helpful
1answer

How do you adjust a fiber cleaver?

Fiber cleavers are used for cleaning and breaking up fiber (straw) during the production of the finished product. They are most often used to clean the final processed fiber or to break up the straw before it is used to make the finished product. Here is a very basic, straightforward answer to this question. If the blade is dull, you have to sharpen it with a stone. A fiber cleaver's head is usually operated by a lever and has a screw mechanism to adjust the angle. A fiber cleaver is the best tool for pottery and ceramics. Want to know more visit our websites. https://fibresales.com.au/test-termination-measurement/fusion-splicer-products/cleave-tool
2/10/2023 3:37:34 AM • Electrical... • 47 views • 0 helpful votes
0helpful
1answer

Trying to find a cooling fan for PD3G10000 watt tri fuel generator. mine exploded into pieces

You can purchase a cooling fan for your PD3G10000 watt tri fuel generator from a variety of online retailers. Some popular options include Amazon, eBay, and Generator Parts World.
2/20/2023 10:59:22 PM • Electrical... • 36 views • 0 helpful votes
0helpful
1answer

ECO Throttle switch off no a/c but hi revving

When you switch the ECO switch on your generator to the higher revving setting, the generator's motor should increase its RPMs in order to handle the increased load. However, if the A/C power cuts out and the motor starts revving high, it could be an indication of a problem with the generator's control system or a mechanical issue. It is possible that the control system is not properly adjusting the generator's RPMs in response to the increased load, causing the motor to rev too high and shutting off the A/C power. It's also possible that the generator's governor, which controls the RPMs, is not working properly, and is not able to adjust the RPMs to the correct level. Another possible cause could be the generator's voltage regulator or control circuit, which may not be functioning properly. It's best to have a professional technician diagnose the issue. They will be able to identify the specific cause of the problem and make the necessary repairs. It's also important to make sure that the generator is being operated within the manufacturer's specifications and guidelines to avoid any damage or unsafe operation.
1/13/2023 4:31:57 AM • Electrical... • 88 views • 0 helpful votes
0helpful
1answer

Need wiring diagram for a 82-6 battery charger

Hi. I suggest providing more make and model information to assist finding what you need.
2/18/2023 10:23:04 PM • Electrical... • 35 views • 0 helpful votes
0helpful
1answer

Diagram of battery charger SE-520MA where can I find it

here is something similar... Schumacher SE 5212A Charger Diagram: gqvngtb-undefined-undefined-0.jpg
12/11/2022 8:21:55 AM • Electrical... • 177 views • 0 helpful votes
1helpful
2answers

Yardworks 950 watt inverter generator. Where can I find parts for this unit?

Question edited for clarity. You need the model number, '950 watt' is just an output and the parts suppliers go by model number. The manual for this much larger generator has the contact details for spares. Your 'regulator looking' part is probably the carburetor and just needs cleaning. People leave them a couple of years with fuel in and they gum up. First job is always dump all the fuel and clean the carb, then check the spark plug. The add fresh fuel, because fuel goes bad unless you use a stabilizer. https://www.manualslib.com/manual/1172193/Yardworks-055-0361-0.html ..
1/8/2023 12:00:43 AM • Electrical... • 85 views • 1 helpful votes
0helpful
1answer

My Jetman gg7200cle runs but does not provide any power.

Lorsqu'un g?n?rateur ne parvient pas ? fournir de l'?lectricit?, cela peut ?tre d? ? divers facteurs tels qu'une batterie d?charg?e, une alimentation en carburant vide, des probl?mes de d?marrage, des bougies d'allumage sales ou d?fectueuses, un filtre ? air bouch? ou des probl?mes de pompe ? carburant. Il est conseill? de v?rifier d'abord la batterie, le niveau de carburant et les bougies d'allumage et de consulter un m?canicien si n?cessaire pour une inspection plus approfondie.
1/29/2023 9:10:42 AM • Electrical... • 50 views • 0 helpful votes
0helpful
1answer

2004 model Ingersoll Rand G5H generator Idle control not working, generator runs fine, but at full throttle all the time

https://doc.pegamo.es/www/componente/doc/1D04724D51D748EC93112C58CEA2C441.pdf -----------------------http://chibupamaquinaria.com/wp-content/uploads/2019/06/Doosan-Portable-Power-Aftermarket-and-Technical-Manual-2018.pdf
12/21/2022 3:02:25 AM • Electrical... • 120 views • 0 helpful votes
0helpful
1answer

Fuse size for air handler (Carrier 40AQ024300BU)

You should always replace with what was originally installed. The 45 amp fuse protects the unit, the 60 amp breaker protects the wiring by its gauge (thickness) and the unit itself. https://www.google.com/search?q=Fuse+size+for+Carrier+air+handler+40AQ024300BU ..
12/25/2022 5:13:07 PM • Electrical... • 95 views • 0 helpful votes
0helpful
1answer

8700 predator no electric start just makes a sound starter won't engauge

harbor FRIGHT(pun) gen. asking the blind this.? and deaf i can not see it fail or hear it fail so any savvy answer is just generic. well did you pin the engine by hand first. flywheel exposed if engine is dry of oil and seized no engine cranks, like that. my gen, has rip cord start and electric start both, so if battery does the generator is not useless, amazing no? useful at all times. answer 2, starter spins (it) and starter spins flywheel and crank fast but will not start. 1: oil level low and spark is cut by it on purpose 2: spark good tested, good. runs on test fuel now but for 3 seconds 3: gas is bad. 4:making filter clogged too. 5:making carb clogged too 6 or bugs built nest in air cleaner and no air for engine to run. now. i think I got them all if switches not set wrong.
12/23/2022 2:56:51 PM • Electrical... • 74 views • 0 helpful votes
Not finding what you are looking for?
GMC Logo

26 questions posted

Ask a Question

Usually answered in minutes!

Top GMC Electrical Supplies Experts

Brad Brown

Level 3 Expert

19187 Answers

john h

Level 3 Expert

29494 Answers

ADMIN Andrew
ADMIN Andrew

Level 3 Expert

66949 Answers

Are you a GMC Electrical Supply Expert? Answer questions, earn points and help others

Answer questions

Manuals & User Guides

Loading...