GE Freezers - Page 11 - Recent Questions, Troubleshooting & Support
GE Refrigerator Light Switch
What is the issue with it. Not coming on or does it work intermittently. I need a little more detail. Thank you
Cause for burning smell from lower back of upright freezer
your freezer might be having blockage on the drain pipe thus not allowing water to flow on the drain tray if the drain tray is mounted on the compressor and its dry then the compressor or the condensor pipes are burning the drain tray. the solution to this problem is to service your freezer
1/24/2013 7:13:15 AM •
GE Freezers
•
Answered
on Jan 24, 2013
GE Profile Arctica not making ice
Check to see if the fuse for the icemaker is blown. Check to see if the linkages are moving. Check the activation motor is getting power.
Freezer doorpops open when close
Sorry to read about your problem, I hope this helps you out.
The gasket seals are getting weak.
I tried to help you. Please help me and Rate/Vote on my response. We take the time to answer your question. take the time to rate us.Thanks and good luck
4 Thumbs - Very Helpful
3 Thumbs - Helpful
2 Thumbs - Somewhat Helpful
1 Thumb - Not Helpful
12/4/2012 10:24:41 PM •
GE Freezers
•
Answered
on Dec 04, 2012
GE FUF14 14DPHRWH purchased 082105.
I don't knowabout the ONLY solution. Is the drain plugged? If so the condenser could be frozen over and therfore no cooling even though fan, compressor and defroster are working. How is 134 level? 124 WILL run below 55 degrees. Duh, that's what's in your car and it will work before the engine compqartment is warm. It may not work as well because of the coefficient of expansion/contraction but it still does "work."
Worked fine unplugged it and plugged it back in lights on but compressor wont come on
Let see if by chance the defrost timer is stuck in defrost. Here is a photo of the back section of your Click Here=>
FUF17DMRWH System Components Item number 121 is the defrost timer and I want you to take a flathead screwdriver and slowly turn the timer dial clockwise until the compressor starts or stops. If doing this will cause the compressor to start you will need to replace the=>
WR09X10154 Defrost TimerIf this is not the problem I want you to feel the top of the compressor to see if it is hot or too hot to keep your hand on top. This test you will need to have the freezer plugged in and set to come on. Doing this tells me that the compressor is trying to start but cannot. If this is the case then we will need to replace the start components listed as number 119=>
WR08X10038 Overloadand part listed as 128=>
WR62X10058 Run CapacitorLet me know what you find and I will help you locate why the compressor is not running, Thanks
Sea Breeze
Not finding what you are looking for?