Electrical Supplies - Page 9 - Popular Questions, Answers, Tips & Manuals

1helpful
1answer
0helpful
1answer

FRANZUS MODEL 18 Travel Adapter INSTRUCTIONS.

Question edited for clarity. Question moved from Microwave Ovens. Throw it away, they all sound dangerous and not to modern code. :>D https://hunterfone.diarynote.jp/202109151913477206/ https://www.google.com/search?q=FRANZUS+MODEL+18+instructions ..
4/10/2023 2:45:08 PM • Electrical... • 63 views • 0 helpful votes
0helpful
3answers

I have a Sony xr65a80j tv that will immediately trip a circuit breaker when I try to plug it in.

you have a short in the unit need a meter to test and check or send out for repair
4/3/2023 8:37:45 PM • Electrical... • 67 views • 0 helpful votes
1helpful
1answer

Can you use 12/2 romex for low volage lighting

Technically, NO. Using Romex cable inside a buried conduit is NOT ACCEPTABLE as a buried conduit is considered a damp location due to the potential for water condensation inside the conduit and Romex is not rated for wet or damp locations. To meet code requirement for conductors inside a conduit you'll need to meet 3 major requirements 1. All conductor insulation must be rated to the highest voltage of any circuit inside the conduit. 2. A buried conduit is a damp location. 3. Conduit capacity restrictions.
4/12/2023 3:24:37 AM • Electrical... • 53 views • 1 helpful votes
0helpful
2answers

How do I reset my pin on a DSE 7320 Deep Sea Electronics controller for a generator?

My unit will go into start mode when I change from auto to Manual
12/23/2022 6:01:46 AM • Electrical... • 968 views • 0 helpful votes
0helpful
1answer

I need the wiring diagram for 67680 avr generac, where togo the exiter wiress ans sensing wires

Unfortunately, Generac does not provide wiring diagrams for their products. You will need to contact a local Generac dealer or service center for assistance.
2/19/2023 4:24:16 AM • Electrical... • 186 views • 0 helpful votes
0helpful
2answers

Where can I get an On and Off fuel valve for 69 15 generator. Where do I order one or get one out?

Question edited for all the typos. Too vague to answer. All question need full 'make model (what it is)' or it is all guesswork. The information you provided this. If it is a 1969, write it in full' or make it '69. To get good answers, you have to ask good, detailed questions. https://www.google.com/search?q=69+15+generator You can probably get all parts from here

Jacks Small Engines: Lawn Mower Parts ' Small Engine Parts

Jacks Small Engines https://www.jackssmallengines.com Call our knowledgeable customer service department 1-877-737-2787. We proudly stand by our mottto "After the Sale, It's the Service That Counts!" ...
5/2/2023 3:10:35 AM • Electrical... • 32 views • 0 helpful votes
1helpful
1answer

Can I keep my round dimmer switch?

Remove the knob and spray WD40 into the stem and it will free it up. I do this periodically. Or you can still buy them, they are made by Lutron. I have two of them. https://www.google.com/search?q=round+dimmer+switch ..
4/23/2023 6:04:31 PM • Electrical... • 37 views • 1 helpful votes
0helpful
1answer

DeVilbiss GB5000 Type 2 Generator. The silver piece on flywheel must be broken. It won't turn over when pulling the starter cord. How do I replace it please?

Question edited for clarity 'Devilish' to DeVilbiss GB5000 Type 2 Generator. You just unbolt the pull starter assembly from the side of the engine. There is a clutch type unit that grips the crankshaft. https://www.google.com/search?q=devilish+gb5000+generator+parts
4/16/2023 1:54:39 PM • Electrical... • 41 views • 0 helpful votes
0helpful
1answer

Predator 3500 AC Generator. Error 5 code. What does it mean?

Error code 5 on a Predator 3500 AC generator typically indicates an issue with the generator's fuel system. The error code may be caused by a problem with the fuel pump, fuel filter, fuel hose, or fuel tank. It could also be caused by a problem with the generator's carburetor or fuel injection system. To troubleshoot the error code 5 on your Predator 3500 generator, you can try the following steps:
  1. Check the fuel level in the tank. If the tank is empty or low on fuel, fill it up and see if the error code goes away.
  2. Inspect the fuel hose for any cracks, kinks, or leaks. Make sure the hose is properly connected to the fuel tank and fuel pump.
  3. Replace the fuel filter if it is clogged or damaged.
  4. Check the fuel pump for any issues. The fuel pump may be malfunctioning or damaged, or it may not be getting enough power.
  5. Check the carburetor or fuel injection system for any issues. The carburetor or fuel injectors may be clogged or malfunctioning, or there may be a problem with the fuel pressure.
If these steps do not fix the error code 5 on your Predator 3500 generator, it may be necessary to consult a mechanic or the manufacturer for further assistance.
1/3/2023 4:43:57 AM • Electrical... • 601 views • 0 helpful votes
0helpful
1answer

How do I throttle down Black Max generator?

You adjust the idle speed. The manual is vague, but there should be an adjuster with a visible spring on the carburetor body or throttle linkage. https://www.manualslib.com/manual/1189243/Black-Max-Bm903600.html?page=22&term=speed&selected=2#manual The idle speed is dependent on the engine make ..
2/3/2023 10:48:55 PM • Electrical... • 236 views • 0 helpful votes
1helpful
2answers

What is the valve clearance on a ryobi rg 7900k generator?

0.15mm +-.02 intake. (.006 in)
0.20mm +-.02 exhaust (.008 in)

engine cold
1/14/2023 8:23:36 PM • Electrical... • 358 views • 1 helpful votes
0helpful
1answer

I need to know what wires go were on a Kraft 6000 watt generator please?

Question edited into written English, 'no' and 'know' are two different words. And did you mean King Craft? There is none called 'Kraft'. Also model numbers are need in such questions, 6000 watt is just the output. some help in the link, but no idea if it is relevant to what you have. https://www.google.com/search?q=kraft+6000+watt+generator+wiring+diagram The correct search query for this is; make model wiring diagram nothing else..
3/10/2023 8:47:48 PM • Electrical... • 66 views • 0 helpful votes
0helpful
2answers

My ryobi rg-2600i does not have a reset button. How do i reset the overload

  • Unplug any appliances or devices that are connected to the generator.
  • Turn off the fuel valve, and let the generator cool down for at least 10 minutes.
  • Check the oil level in the generator, and add more oil if necessary.
  • Check the air filter and clean or replace it if it is dirty.
  • Turn the fuel valve back on and start the generator.
  • Check the spark plug to make sure it is in good condition and properly seated. If it is dirty or damaged, clean or replace it.
  • Check the fuel line to make sure it is not clogged or damaged. If it is, replace it.
  • Check the fuel filter to make sure it is not clogged. If it is, clean or replace it.
  • Check the carburetor to make sure it is clean and functioning properly. If it is dirty or damaged, clean or rebuild it.
  • Check the voltage regulator to make sure it is functioning properly. If it is damaged, replace it.
  • Check all of the connections on the generator to make sure they are secure and not damaged.
  • Check the generator's fuel tank to make sure it is full and that the fuel is fresh. If the fuel is old, it may have gone bad and will not burn properly.
  • Check the generator's battery to make sure it is charged and functioning properly. If the battery is dead or damaged, the generator may not start.
  • Check the engine for any visible signs of damage or wear. If you see any cracks, leaks, or other issues, the engine may need to be repaired or replaced.
  • I know it is a basic checklist... I just hope that I might have thought of something that you did not? two minds are better than one... sometimes.
1/8/2023 9:59:07 AM • Electrical... • 311 views • 0 helpful votes
0helpful
1answer

Model 1001 311 060 Motion security light

Try setting DUAL BRIGHT to OFF.

Be sure daylight sensor is clear.

Try putting unit into test mode and it should be full ON or full OFF. If not, then likely unit is bad.
3/29/2023 7:45:22 PM • Electrical... • 39 views • 0 helpful votes
0helpful
1answer

I am replacing an old dimmer with a new one.

Easiest Way to Replace a 3-Way Switch If you're simply swapping an old 3-way switch for a new one, use this simple trick to get the wiring right: Before disconnecting any wires on the old switch, find the wire attached to the common screw terminal and label it with a piece of tape. Then, you can disconnect all three wires from the switch, as well as the ground wire. Because the other two wires (the travelers) are interchangeable, it doesn't matter which of the traveler screws you attach them to-there's no need to label them.
3/20/2023 2:38:15 PM • Electrical... • 47 views • 0 helpful votes
0helpful
1answer

Why is my SaniFlo Saniaccess 2 tripping my GFCI constantly?

GFCI or RCD tripping is either moisture has entered the motor body or there is a wiring fault. Neither of which would I consider a warranty issue especially noting the age. Call an electrician to diagnose the fault first then take it from there.
2/19/2023 2:31:34 PM • Electrical... • 67 views • 0 helpful votes
0helpful
1answer

Kawasaki GA1400A Generator. It starts fine, 12 volts okay, but no 230 volts.

Question edited for clarity. Question moved from Motorcycles to Generators category. Some help in the link, but not as much as I would like https://www.google.com/search?q=Kawasaki+GA1400A+no+230+volts+output ..
1/8/2023 12:06:29 PM • Electrical... • 123 views • 0 helpful votes
Not finding what you are looking for?
Electric Logo

119 questions posted

Ask a Question

Usually answered in minutes!

Top Electrical Supplies Experts

vince

Level 3 Expert

2530 Answers

NOEL
NOEL

Level 3 Expert

8606 Answers

john h

Level 3 Expert

29494 Answers

Are you an Electrical Supply Expert? Answer questions, earn points and help others

Answer questions

Manuals & User Guides

Loading...