My spa is at 89 and its set for 104 and the pump will not cut on what is the problem
You may be in economy mode. Economy only heats the water during a programmed filter cycle. You want it to be in standard mode which turns on the hot tub once the water is 2 degrees below the desired temperature. There should be a mode or program button on your topside. One some systems you'll have to hit prog/mode button then the temp up button to change the mode. There is also a sleep mode. Never used it not sure what it's for.
What does code ic mean?
I have not seen an ic error code. I have seen ICE several times. So either you do not have the original pack that came with the spa or your display may be malfunctioning.
What is your hot tub doing while the ic code is pressent?
Portable Hot Tubs and Spas On Sale
Dream maker ez spa has power but jets won't turn on. Fuse is fine and unit is getting power
Thanks for the question! It could be several different issues. First, It's possible the topside jet button is malfunctioning and may need to be replaced. Is there any type of error message flashing on the topside display? Second, The pump may be bad, If it's a 2 speed pump it's possible to still circulate the water and maintain temp while the pump is malfunctioning. Depending on your level of "do it yourselfness" you may attempt to troubleshoot and repair it on your own. Checking for an error code on your topside is the best 1st step to take. I wish I could be of more assistance however, without being able to inspect it myself those are the best suggestions I can muster. Good luck & I hope I was able to provide at least some assistance. =)
Spa was below temp, now it heats and won't shut off.
Is your spa overheating, heating up past 104 degrees?
If so, you have a contactor (or relay) stuck shut and the spa should go into OH at 108 degrees.
d
If your hot tub is only heating to 104 or what ever temp you have it set at and the motor runs 24 hours a day there are a couple of things you'll want to check.
First, make sure that you do not have the pump set to run 24 hours a day.
Second, you'll want to see if the pump icon is lit up on the control panel. You will want to check to see if the icon is on while the spa is supposed to be resting. During filter cycles the icon will be lit. If you are not in a filter cycle and the pump is on while the icon light is off, you have a stuck contactor (relay). The relays can be found online for less then a couple of dollars.
If you have any more questions feel free to ask.
Spa wont turn on,there was a lightening strike.could that have ruined the spa
check the GFIC trip it and reset it, next see if any lights come on in the spa. if no you might want to check for voltage at the spa, if you have the set voltage 115 OR 230v . I would check fuses on the control panel .
Hope this gets ya running again. ask if you need morwe help, and don't forget to vote if i was of help