Science & Laboratory - Page 7 - Answered Questions & Fixed Issues

0helpful
1answer

How can I turn off the zeiss Humphrey? only from the shut down button or there is a function from the software?

This is a brand name, not a specific device and model. That said, here is a page describing mode switch in the setup screen using the touch screen for a specific device. I assume a touch screen would have an icon for turning a device off. Zeiss HUMPHREY 720i User Manual System Setup
6/16/2018 5:01:20 PM • Zeiss Science &... • Answered on Jun 16, 2018 • 1,063 views
0helpful
1answer

BSA 3-12 x 50 Rifle Scope

But a new scope. Having the crosshair reseated will cost you more than getting a new BSA scope.
4/3/2018 1:49:24 AM • Science &... • Answered on Apr 03, 2018 • 702 views
0helpful
1answer

Humphrey ATLAS topographer- turning joystick no longer raises or lowers topographer

You need to replace the belt that drives the elevator gear from the joystick. If you need help with this feel free to call or email [email protected] 815.325.5838
4/3/2018 1:47:36 AM • Zeiss Humphrey... • Answered on Apr 03, 2018 • 834 views
0helpful
1answer

I need service manual for sanyo mac 1200 autoclave

Manuals are available from PHC. Email [email protected] or call Technical Support at 800-858-8442 ext. 48299.
4/3/2018 1:42:57 AM • Science &... • Answered on Apr 03, 2018 • 819 views
0helpful
1answer

Can't open main door after a spin J6B

Disconnect the main power. Wait 5 minutes and then reconnect power. Door lock will release. If this doesn't work, the locking relay needs replacement.
4/3/2018 1:22:32 AM • Beckman J6B • Answered on Apr 03, 2018 • 734 views
0helpful
1answer

My sterilizing autoclave, SES 2000 Little Sister has flashed with error ELECT on the screen, it apparently has something to do with a power cut we may of had today, but how do you fix it?

Check the fuses located on both sides of the mains connection in the back of the autoclave. One of them has blown. If both check ok, then check the connection tho the mains. You may have a faulty ground. If you are not comfortable doing this, contact Eschmann at tel:+44 (0)1903 753322 Fax: +44 (0)1903 875789 [email protected]
4/3/2018 1:20:07 AM • Science &... • Answered on Apr 03, 2018 • 4,589 views
0helpful
1answer

Where can I find a Digital Blue microscope QX5 software? My CD is damaged.

I have a copy for Windows 7 32 bit. You can download it from https://drive.google.com/file/d/1Y650G_x6m6Efk8n6P5xQKBHvrMuIV8yc/view?usp=sharing
3/27/2018 11:44:20 PM • Digital Blue... • Answered on Mar 27, 2018 • 934 views
0helpful
1answer

I have a IEC Centra-MP4R Centrifuge. The door will not open when I press the open button after a completed run. Does anyone know how to fix this?

I know nothing about the device, but it reads like you forced the door into a wedged position and it's stuck there. I would gently pry at it to get it past the "wedge", then study the mechanism to see whether the actual latch is broken, or just out of position. Please click the Comment link to respond.
3/21/2018 1:41:34 PM • IEC Centra-MP4... • Answered on Mar 21, 2018 • 982 views
0helpful
1answer

Which Is The Best Laboratory Chain For Conducting Tests And Analyses?

Choosing the right laboratory for conducting various tests and analyses can be a tricky affair. If there is any discrepancy in readings, it can be cause quote a stir. Thus, it is imperative that the staff operating the equipment of the laboratory must be expertly trained. The equipment itself must be top notch in quality. LiveScanLabs has managed to meet all this criteria. They have centers in Hialeah, Hollywood, Fort Lauderdale, Pembroke Park and Pembroke Pines. They conduct Fingerprint Analysis, Fingerprint Testing, **** Analysis, **** Testing, DNA Analysis, DNA Testing and regular health tests as well. Visit their website at www.livescanlabs.com.
3/3/2018 10:36:45 AM • Science &... • Answered on Mar 03, 2018 • 603 views
0helpful
1answer

Seems like solvent A and B are confused

By convention solvent A is the aqueous solvent and solvent B is the organic one, so the designation seems to be right. The baseline does not always raise with the increasing amount of solvent B, it depends how steep is the gradient.
2/28/2018 8:55:38 PM • Varian Prostar... • Answered on Feb 28, 2018 • 585 views
0helpful
2answers

Error 102 microscope not plugged in

One has to have a compatible operating system with the correct driver, Your computer operating system must be set for reading the USB port as a video device, f you are able to read any data from the scope you should also check firmware version against the manufacturer's latest revision. Also suggest you download the operator's manual from the manufacturer's site.
2/3/2018 11:11:41 PM • Digital Blue QX5... • Answered on Feb 03, 2018 • 1,001 views
0helpful
1answer

Just aquired an old olympus

Olympus makes good microscopes so you have done well and stereo microscopes are so much nicer to use than singles. As far as cleaning the lenses goes, buy a good quality camera lens blower brush and also a can of compressed air like the ones used for computers. Blow any loose dust hairs etc off with the can of air and then use the brush for anything remaining. If there are fingerprints or grease on the lenses then clean them using camera lens cleaning fluid and lens tissue but make sure all debris and dust are removed first or you may scratch the lenses. In general try not to use anything more than air and a brush unless absolutely necessary. Another option for removing fingerprints etc is to use a "lens pen" with caution. The ones sold for cameras work well but may be too large. They make some smaller ones for cleaning camera sensors and those might work better for the relatively small microscope lenses or just cut the regular lens pen disk to make it smaller. It is just as important to make sure the lens is dust/debris free when using the lens pens. Low power stereo microscopes often allow you to put on a single magnifier lens in front of the main objectives to increase magnification. Do a bit of searching to find what are options for your model.
1/18/2018 6:19:51 AM • Olympus Science... • Answered on Jan 18, 2018 • 2,073 views
0helpful
1answer

Rotor seems to be frozen on to spindle; all

Have you seen this video with advice? http://www.benchfly.com/video/41/removing-a-stuck-centrifuge-rotor/ Another tip is to cool the rotor down (either by getting the refrigeration to kick in if it is a refrigerated centrifuge) or perhaps by filling the the rotor with tubes full of ice-water (or something colder...). Everything will shrink slightly, which means the rotor will become a slightly looser fit on the shaft.
1/17/2018 7:39:17 PM • Sorvall Science... • Answered on Jan 17, 2018 • 2,143 views
0helpful
1answer

Heraeus pico biofuge

Are you sure that the lid safety interlock switch isn't damaged/dirty? If the centrifuge can't detect that the lid is closed it will never start. Sometime it just needs an extra push down on the lid.
1/17/2018 7:28:09 PM • Science &... • Answered on Jan 17, 2018 • 1,734 views
0helpful
1answer

CME Incoming calls Busy always

Say What?
1/16/2018 12:03:52 PM • Cisco Press Ip... • Answered on Jan 16, 2018 • 749 views
0helpful
1answer

Premiere MS01u microscope bulb flickers. Won't come on.

It sounds like either the bulb is loose or the connection between the bulb socket and a wire is loose. To check both, Loosen the screw knob on the underside of microscope and open the panel to expose the bulb. Use a small screwdriver to loosen the screws holding (the two screws closest to the bulb) the prongs of the halogen bulb. Note that the prongs of the bulb are held in place by small brass plates which shift slightly when the screws are loosened. Remove the old bulb. Important: Do not touch the new halogen bulb with bare hands. Wear gloves or hold the bulb using tissue or lens paper. Body oils may damage the halogen bulb. Insert prongs of replacement bulb into top of socket (above the brass plate) and tighten screws slightly. (The brass plates will move up to hold the prongs in place.) Close door and hand tighten the thumbscrew knob. If this does not work, contact Premier for assistance: Premiere® Microscope Service, 7241 Gabe Court, Manassas, VA 20109 (703) 330-1413
1/15/2018 6:35:24 AM • Science &... • Answered on Jan 15, 2018 • 929 views
0helpful
1answer

Hello, does anyone recognize E61 error code for Euronda E9 autoclave please?

The error E61 indicates that your water pump has failed or is not active. You should check the pump and replace it if needed. You should also check the steam generator sensor and replace it if needed. For more information, contact Euronda at Water inlet pump inactive or call (+39) 0445 329811 (Vicenza, Italy)
1/15/2018 6:14:50 AM • Science &... • Answered on Jan 15, 2018 • 973 views
0helpful
1answer

MS-01U Parts

If this is a microscope, the part you are referring to is the stage control. You can get the part from C&A Scientific at http://www.cnascientific.com or by calling 703.330.1413
1/15/2018 6:02:43 AM • Science &... • Answered on Jan 15, 2018 • 599 views
0helpful
1answer

Broken microscope light

1/9/2018 1:37:21 PM • Science &... • Answered on Jan 09, 2018 • 534 views
Not finding what you are looking for?
Science & Laboratory Logo

Ask a Question

Usually answered in minutes!

Top Science & Laboratory Experts

Collins Mccoy
Collins Mccoy

Level 2 Expert

58 Answers

Don A
Don A

Level 3 Expert

4495 Answers

ADMIN Andrew
ADMIN Andrew

Level 3 Expert

66963 Answers

Are you a Science and Laboratory Expert? Answer questions, earn points and help others

Answer questions

Manuals & User Guides

Loading...