I have a GE 5805WS6
If your unit was initially working fine and you find that it recently intermittently works with the outdoor unit then unfortunately there is not much you can do. The cause is other type units transmitting on the same frequency, eg: internet. You can try changing frequency, but I found the frequency spectrum here full with wifi / internet modems / cameras, so not much can be done. It does still lock on but there are long gaps of nothing. Perhaps a mod to boost either tx or rx ?
Connection error time out 3062
hi did you have an answer, or did you manage to solve your problem i have the same If anyone can help with any tips please
Weather station won't work
i have the same problem and have had 2 of these now. outside unit blinks like it is transmitting but nothing on base. SYNC per manual does not fix it.
How do you calibrate and Abney Hand Level? The one
You need a carpenters level longer than the Abney level. Find a smooth flat level surface like a table with the carpenters level. Double check the carpenters level by turning it 180 degrees and see if it still shows level. If it doesn't get another carpenters level. Set the Abney level at zero and lay it on the carpenters level or the flat table. The bubble should center on the index line. There is usually two screws that allow you to move the glass tube (and the index at the same time) to center the bubble and index if it is off. Then check your findings. Put a piece of contrasting tape on a wall at eye level. Walk back 20 or 30 feet and see what the angle reading on the Abney level shows. If you keep your feet in the same position; that is your eye at the same level, you should read zero.
My gbt-502A tester doesn't work.
Some GBT models come fused, try replacing the fuse in the device (if it has one) and see if that works for you. also you may one to check yoru battery terminals any corrosion build up can block you connection between your battery and the tester. Use a tooth brush to clear the terminals. Hope that helps
How do you change the batteries in a greenlee 1010 tester?
The black cap with pocket clip PULLS off. It does not screw on. May be tight. I used a knife to to pry between the yellow barrel an the cap, to get it started. Pull the cap off and dump the old batteries out. Dispose of the dead batteries appropriately, please. It takes 2 LR44 coin cells, or equivalent. The (+) side of the cells go into the barrel first - both with same orientation, with the (-) ends (the buttons) toward the opening. Then reinstall the cap - line it up so the clip will align with the window in the yellow barrel, then just press it all the way into the yellow barrel. Done.