What is (60 g) of grease
181490-7 grease 30g 1 pcs complete be shure there are no cured o-rings or bad gaskets .
188015-8 its the maintenance kit for the service it contains already this 30 grams grease, where come 60 grams advise ? i like also to use some more grease by this heavy kind of hammers.
But tools like Hilti with liquid (oil) lubrication and very tight tolerance ball bearings if there is to much (turmopol) oil used it will be damaged, and too little oil also its calculated. I cannot give garantee that 60 grams are advised by a makita service, if you order a maintenace kit ask the seller about why it only contains 30grams. The information to use 60 grams ? doubt.
Tool wont scrape
254031-3 pos14 part inlay key can be damaged pos 11 drive rod 315146-2 can broken IF mechanical damage or dried out by leaking gasket / orings.
For better repair use after a repair of some parts an maintenance kit
193394-1
If the working hours are on it, but also after an repair on other parts because leaking tools can be dried out and give cured o rings in a very short time by building up overheat temperature inside and will not build up pneumatic power it will not do the job and is not good for physical strain.
Hammer action power there but weak
It is hard to understand what you are asking, however I have found that with the SDS drills one does NOT want to crowd them but just let the tool work with light pressure...
Switch for kango 950 S
- The total condition of the seal anvil piston and striker are very important for the total condition of impact when spending a service kit (maintenance) when there is leakage at the front part everything will be hot inside and the rings will harden again quickly.
kango 900 950 round switch housing
8/16/2018 7:56:48 PM •
Hammering
•
Answered
on Aug 16, 2018
How to fix
193243-2 revision maintenance service kit
With all necessary rings and fat , beware before ordering an service kit take the time to remove all parts of the spindle ringing on the hammer tube spindle for cracks the chisel sds impact bold striker must be even air-tight on the chisel impact bold not leaking grease out of it , if its leaking the air flow will burn the o-rings in a very early time because of the building heat made by the leaking airflow . and loose of lubrication. fat grease .