Grilling - Page 6 - Answered Questions & Fixed Issues
I have a Weber gas grill, and I just replaced the
Don't worry, you'll be grilling in no time, if you follow these instructions:
1. Turn the gas tank valve OFF.
2. Disconnect the grill's hose from the propane tank and wait 5 minutes.
3. Reconnect the hose to the tank and open the tank's gas valve VERY, VERY SLOWLY (Slow Motion, slow).
Once the valve is fully open light one burner and turn it to HIGH. Has the flame height returned to normal? If so, light the remaining burner and turn it to HIGH. Do both flame heights look normal?
If so, you solve the problem! Remember to always turn the tank valve ON Very, Very Slowly.
Hope this helped you. Please let me know and Happy Grilling!!
3/27/2022 7:44:49 PM •
Weber Baby Q...
•
Answered
on Mar 27, 2022
•
950 views
Changing electrical smoker element does not heat up control panel works.
Check the new element with a test meter / multimeter, set to ohms. check the old one too. If the old one has continuity, then the issue is the wiring, the thermostat / thermistor or the control panel itself.
make model (what it is)
in all questions please.
1/27/2022 7:07:33 PM •
Grilling
•
Answered
on Jan 27, 2022
•
405 views
How do I adjust the side burner flame on a Weber grill?
The burner has a fixed orifice, but there may be an adjustable air shutter (to adjust more or less air) at the end of the venturi tube that inserts over the orifice. If not, also try removing the gas valve knob and see if there is a small screw inside the shaft that you can adjust the flames. Most stoves have these. Also be sure the burner hasn't been spilled on. it may just need to be cleaned for a proper flame.
12/23/2021 12:11:55 PM •
Weber Genesis...
•
Answered
on Dec 23, 2021
•
1,859 views