Electrical Supplies - Page 3 - Popular Questions, Answers, Tips & Manuals

0helpful
2answers

My husky 3750 generator will start but it will not produce any power. I plug a radio into it and it won't power it up. What's wrong?

Troubleshooting and videos

What causes no electrical output in Husky generator?

JustAnswer https://www.justanswer.com > small-engine > 4e3fa-hu... Dec 29, 2010 - Let me know what you find, and we will continue of if need be - but the single most common issue with these sets, by far, is a bad voltage ... 1 answer ยท Top answer: Ok, here is what you need to do next. Please read these instructions carefully, and do the ...

Husky Generator won't start

Repair Clinic https://www.repairclinic.com > RepairHelp > Husky-G... Here are the most common reasons your Husky generator's engine won't start - and the parts & instructions to fix the problem yourself.

Fixing Portable Generators - No Power

Aurora Generators https://www.auroragenerators.com > post > fixing-portab... Mar 1, 2022 - The most common cause of portable generators failing to produce electricity is from the loss of residual magnetism.
10/14/2023 6:57:37 PM • Husky Electrical... • 35 views • 0 helpful votes
0helpful
1answer

Generac Standby Generator. I have a red blinking light on on the OFF button on the Guardian 2.0 control panel?

Question edited for a lot more clarity. Model and KVA helps. Question moved from Televisions to Generac Guardian category. Information to troubleshoot in the link and video. https://www.google.com/search?q=generac+guardian+standby+generator+switch+off+led+flashing+red ..
9/20/2023 4:50:42 PM • Generac... • 53 views • 0 helpful votes
0helpful
2answers

What is the colored wire positions on a craftsman 2400 mower key switch

See following URL for complete wiring diagram.https://www.searspartsdirect.com/model/3x23oa7iyt-000247/craftsman-917203831-front-engine-lawn-tractor-partsSwitch Terminal to circuit color.B RedS WhiteM Black (Black/white)A1 BlueA2 BlackL BlackG BlackUnfortunately 4 of the circuits are not uniquely color coded. If the black wires have been disconnected from the switch socket then it will be necessary to identify each black wire to its respective circuit.9_28_2023_9_24_45_pm.jpg9_28_2023_9_24_46_pm.jpg
9/28/2023 5:02:03 PM • Craftsman... • 44 views • 0 helpful votes
0helpful
1answer

Steele Products GG-600N 6000 peak Watts Portable Generator. Can it be converted to electric start?

Question edited for a lot more clarity. There is a video that might help, but there is no conversion kit. What some people do it remove the recoil start and use an impact driver or electric drill with a socket that fits the bolt on the end of the crankshaft. https://www.google.com/search?q=Steele+GG600N+generator+convert+to+electric+start
10/29/2023 10:28:09 PM • Electric... • 23 views • 0 helpful votes
1helpful
1answer

I need a replacement thermostat for my Robertshaw 9420, will a Robertshaw 9560 be a close replacement?

Replacing a thermostat with a different model requires careful consideration of compatibility, wiring, and features. To determine if a Robertshaw 9560 can replace a 9420:
  1. Verify compatibility with your HVAC system based on manuals.
  2. Check wiring compatibility or consult an HVAC technician.
  3. Compare features to meet your heating/cooling needs.
  4. Ensure programming aligns with your requirements.
  5. Confirm power requirements match your setup.
  6. Assess the user-friendly interface.
  7. Check thermostat size and mounting options.
  8. Prefer professional installation if unsure.
  9. Investigate warranty and support for the 9560.
9/2/2023 1:42:14 PM • Electrical... • 76 views • 1 helpful votes
0helpful
1answer

Wacker Neuson DPU 5545 Vibratory Plate. I turn the key, it beeps but it won't turn over. What do I need to check?

Question edited for clarity, 'Nelson' to Neuson, and 'DPU' to BPU. Question moved from Cars and Trucks to make model category. Having read the manual, it sounds like the 'Oil Alert System' on Page 31. https://www.rentalex.com/wp-content/uploads/2017/04/BPU4045A_Operators_Manual.pdf ..
9/27/2023 12:08:46 AM • Wacker Neuson... • 42 views • 0 helpful votes
0helpful
1answer

I have a Yamaha Ef2600 fw generator that starts and produces voltage and current but also gives out a 'clunking' noise on a 2 - 4 second cycle. What is wrong with it?

Based on the search results there are a explanations, for the clunking noise in your Yamaha EF2600FW generator; 1. Load handling; One potential reason could be that the generator is facing difficulties in managing the load, which could be due to fuel or air supply. This can result in the generator producing a clunking noise. 2. Fuel shortage; Another possible cause might be a lack of fuel supply to the generator leading to a knocking sound. It is advisable to address this fuel issue before operating the generator to prevent any damage. 3. Storage conditions; The clunking noise could also arise from storage conditions. Over time certain components like piston slap or dry rod bearings may develop problems resulting in sounds when the generator is running. To diagnose and resolve the problem with your generator it is recommended that you take the steps; Check and ensure a fuel supply. If needed, clean or replace the carburetor. Inspect the generator thoroughly for any signs of damage or wear in areas like piston and rod bearings. These actions should help. Rectify any issues causing the clunking noise, in your Yamaha EF2600FW generator. If the problem continues you might need to reach out to a technician or get in touch, with Yamaha customer support for help. Always prioritize safety when dealing with generators or any other equipment. If you feel uncertain or uncomfortable about troubleshooting or making repairs yourself it's best to seek assistance, from a professional.
8/25/2023 10:38:59 AM • Yamaha... • 63 views • 0 helpful votes
0helpful
1answer

Robin IR80 PAT (Portable Appliance Tester) Who has a manual and could I receive an email copy please?

Question edited for clarity. Question moved from Computers. There are many PAT Tester manuals here, but no IR80. https://www.pat-testers.co.uk/pages/download-centre Maker address and phone number on Page 1 https://www.manualslib.com/manual/1667980/Robin-Smartpat-5500.html#manual Someone here is willing to email (we don't email anything). We are private individuals just like you, helping others for free. You don't want you email address on a website that gets 11 million views a year! https://www.electriciansforums.net/threads/robin-ir80-pat-tester.113083/ https://www.google.com/search?q=robin+ir80+pat+manual .. General interest video
8/27/2023 3:34:13 PM • Electrical... • 44 views • 0 helpful votes
0helpful
1answer

Wiring diagram for a Schumacher battery charger XC85 Super Charger.

Question edited for clarity. Question moved from Washing Machines category. Here is the Manual. Many of them have the wiring diagrams in them. If you email them, they will sent it to you. Their customer service is excellent. Page 11. https://manualzz.com/doc/51884407/schumacher-xc85-ca-owner-manual ..
8/6/2023 4:02:02 AM • Schumacher &... • 72 views • 0 helpful votes
1helpful
1answer

2014 Fleetwood Storm 28f Cummins Onan generator fuel problem. New pump and rebuilt carb but not getting fuel picked up. Any help would be greatly appreciated.

did you change filter? is fuel supply line pinched or kinked? https://www.youtube.com/watch?v=5_BhETigbMs
9/2/2023 3:51:23 PM • Electrical... • 36 views • 1 helpful votes
1helpful
1answer
0helpful
1answer
0helpful
1answer

Energy Buster

12/13/2023 3:13:19 PM • Solar Electrical... • 11 views • 0 helpful votes
0helpful
1answer

Powerhouse 3100RI has no spark, plug has been changed. Where to look and what to check

It has low oil level cut off which will prevent spark. Check there is sufficient oil in the engine crankcase. Oil level alert sensors are a common failure so if there's sufficient oil then disconnect the sensor. If engine then runs, replace oil alert sensor. Owners manual is available, no fee download, at the following URL. https://www.manualslib.com/manual/722234/Powerhouse-Ph3100ri.html#manual
7/26/2023 9:00:26 PM • Electrical... • 65 views • 0 helpful votes
0helpful
1answer

When I pull start my sportsman 7 hp generator it stops like the piston is stuck but when I remove the spark plug it turns right over

Hopefully you have the correct reach spark plug. Too long and it will jam up the piston.
9/16/2023 6:17:12 PM • HP Electrical... • 20 views • 0 helpful votes
0helpful
1answer

How to wire a Kohler generator starter

8/4/2023 9:18:34 PM • Kohler... • 41 views • 0 helpful votes
0helpful
1answer

TORK rz307. Installed 2 days ago & now I can barely see screen

There could be a few possible reasons for the TORK rz307 screen being frozen and appearing dim. It could be due to a software glitch, a faulty connection, or a defective screen. I recommend checking the connections and trying a reset.
6/10/2023 3:19:06 PM • Electrical... • 143 views • 0 helpful votes
Not finding what you are looking for?
Electrical Supplies Logo

22,739 questions posted

Ask a Question

Usually answered in minutes!

Top Electrical Supplies Experts

john h

Level 3 Expert

29494 Answers

Brad Brown

Level 3 Expert

19187 Answers

CJ Rock
CJ Rock

Level 3 Expert

4424 Answers

Are you an Electrical Supply Expert? Answer questions, earn points and help others

Answer questions

Manuals & User Guides