Braun Health & Beauty - Page 6 - Recent Questions, Troubleshooting & Support
Cleaning station won't stop cleaning after
Most likely you do not properly perform the cleaning operation of the cartridges. It is important to remember that one thing is wrong even the unwitting movement will lead to a malfunction, as in your case with cleaning station. Also, there is often non-quality appliances, especially the vacuum cleaners that's why I always follow to
https://bestvacuum.reviews/roomba-replacement-batteries/ and the customer representatives give me instructions and demonstrate how do it. Before you tend to market - check the completeness of the equipment and the absence of mechanical damage on receipt. In case of detecting external damage when obtaining equipment, fix the number and nature of the damage.
How do you replace a
I replace my Bruan 7680 battery. I place the order for battery from Amazon, cutter& foil from goodmans.net. The following is my procedure
1.Using a small flat screw driver to plier the plastic socket lock (Where the charging located )
2.Disassemble left and right plastic holder
3.Disassemble plastic cover top and bottom
4.Take out the circuit board where the battery mounted on. Please be careful at this process you could ruin the circuit board while taking the old battery out(I used a soldering and a small wood stick just to take the extra flux away from contact to other on the circuit board).It is not as difficult as I thought.
5.During your install a new battery please make sure that the batter pole does not go the same way(Check direction of a battery before
taking it out so you do not put in the wrong direction)
6.Putting them back together.
Note
#special tool required to take out the circuit board from a mounting?My the battery replacement came with the tool)
Model BP4900 series Should this device pump
With brand new batteries installed I turn ON to start the BP4900PH-WE blood pressure test, display show 00 and pressure pum try to start but after several automatic attemps and internal "clicks" sounds, display remain in "00" and pump doesn't star.
Silk Epil 5376
Rotators are too
You will need a star-shaped bit to remove the 2 screws. I would imagine they’re metric as it’s made in Germany. Barring that, a small flat head screwdriver used for eyeglasses will work. Remove the screws over a bucket or something so you don’t lose them, because they’re specific to the SilkEpil and can’t be bought at the hardware store.
When you remove the screws and take it apart, you’ll see the gears inside are clogged with hair. The flaw with the design is that the gear mechanism will suck in a few hairs every time you use it, which build up over time.
Remove the gear unit and use tweezers to pull out all the hair. You can rotate the gears to get it all. On the underside of the tweezer section, there’s a little recessed gear that’s probably clogged with hair too. Rotate the tweezer barrel to turn the little gear, and pull out the hair.
Give everything a good rinse, put it back together, and let it dry overnight. Presto, good as new!
I plan on doing this once a year as regular maintenance.