Condensation

There is no"filter" underneath. There is. however, a tray underneath your fridge, designed to catch any excess water. If you remove the bottom louvered piece in the front on the fridge, you will find, probably on the right hand side, a tray which is engineered and designed to catch any excess water (as if the fridge were defrosting), but there is no "filter" which I know about. Refrigerators are pretty simple machines. They don't typically require lots of maintenance, but they do require monitoring here and there.
1/18/2018 4:57:02 AM • Beverage-Air... • 337 views • 0 helpful votes
0helpful
1answer

My commercial refridgerator stays too cold

Defective cold control thermostat
11/2/2017 7:45:03 AM • Beverage-Air... • 213 views • 0 helpful votes
0helpful
1answer

I have a 7 yrs old beverage air mt27. The issue

That temperature control assembly will most likely be the problem.
10/10/2017 10:27:02 PM • Beverage-Air... • 276 views • 0 helpful votes
0helpful
1answer

MT27 has a noisy fan operation. Doesn't always

There are a couple of possibilities that could be causing this. I believe it is the fan blade. One could be that bracket that holds the fan motor in places could have loose screws, which would cause vibration. Another is that the mounting for the fan motor to the bracket could be loose. Another could be that the fan blade itself is slightly bent. Check the motor brackets screws, fan mounting screws and the blades. If all those are good, making sure the unit is unplugged you can turn the fan blade by hand slowly to see if it is dragging anywhere on the shroud around the coil or the coil itself. You could slightly bend the "clacking" blade to clear is that is the issue. Tom
10/8/2017 3:45:03 PM • Beverage-Air... • 256 views • 0 helpful votes
0helpful
1answer
0helpful
1answer

New compressor installed- wont cool

Check evap for a restriction. Check drier to see if it is installed in the correct direction. Does not sound like a cap tube issue if you can verify flow with nitrogen.
8/16/2017 1:54:03 PM • Beverage-Air... • 126 views • 0 helpful votes
0helpful
1answer

I'm replacing the thermostat on

Not familiar with this thermostat but you can figure it out if you know how to use a meter. Sounds like they want you to run both power and neutral threw the thermostat OR it is one that either opens on temp rise or closes on temp rise. Also, the wire tapped into the black one for the fan is probably to energize the fan 24/7 as the original may have been damaged.
6/17/2017 1:03:03 PM • Beverage-Air... • 292 views • 0 helpful votes
0helpful
1answer

Cdr3-1 top light fixture shorted out on right side

you type in their e-mail address and see if you get a reply most likely you will get an undelivered reply so it will not be legit
5/27/2017 10:15:03 PM • Beverage-Air... • 111 views • 0 helpful votes
0helpful
1answer

I have a 2 door

In general, these units are not to be exposed to temps over 80 degrees. Anything above this and it will struggle to keep temp.
4/22/2017 2:27:03 PM • Beverage-Air... • 247 views • 0 helpful votes
0helpful
1answer

Beverage Air MT17 cools sporadically. I turn the temp control setting to 5 and it will go down to 28 degrees F and the next day it will be at 55 F. I have to turn the control knob to off position then

Low refrigerant would make it inefficient but if it chills to 28° it can't be that bad. I think you have a control issue. The compressor runs when you reset to off & on, then chills until it satisfies the thermostat, then shuts off. But then is not starting again when the temperature rises. You'll need to follow the control wiring to see what contacts are open and not passing power to the compressor. Control wiring is typically 24v ac or 115v ac. There's also the possibility that the compressor is tripping out on overload at 28°. You effect a reset when you turn it off, then on.
3/26/2017 7:21:02 PM • Beverage-Air... • 282 views • 0 helpful votes
0helpful
1answer

Is It A Cooler or a Freezer?

With no heaters or defrost timer, it is most likely not a freezer unless someone removed all that. As best as I can tell, I can not find anything that equates to the temperature and pressures you related to. It could be either low on Freon or the R-12 has been removed and an alternate Freon installed to replace it. Hope this helps.
2/28/2017 10:06:03 AM • Beverage-Air... • 156 views • 0 helpful votes
0helpful
1answer

I have a Beverage-Air MT27 and the door sags down on the side opposite the hinges and also leaves an air gap at the top on that side. I have tried adjusting to no luck. Any suggestions?

can you unbolt lower hinge from Door and put thin spacer between hinge and door. that should lift opposite side.
3/17/2016 10:23:42 PM • Beverage-Air... • 492 views • 0 helpful votes
0helpful
2answers

I have a beverage air mt38 and the copper line is freezing. The beverage cooler does not get cold. How do I fix this ?

Found Freon Leak and Fixed How I Do it
12/31/2015 2:00:42 AM • Beverage-Air... • 609 views • 0 helpful votes
1helpful
2answers

Why is my Beverage-Air refridgerator running all of the time?

Door seals torn, poor air circulation over condenser coils or evaporator coil, defective thermostat, not defrosting or low on Freon. APPLIANCE 911
12/15/2015 6:30:36 PM • Beverage-Air... • 621 views • 1 helpful votes
0helpful
1answer

I have water accumulating in the refrigerator compartment. How do I access the condenser area to figure out what is wrong.

http://beverage-air.com/uploadedFiles/docs/SPE60%20Cutting%20Top.pdf REFRIGERATION More robust refrigeration system provides added capacity and efficien-cy. Systems are designed using CFC free R134a refrigerant. Forced air from evaporator is moved under pans, which are recessed 2" from top of cabinet. Forced air over the condenser is drawn from back and bottom of cabinet. Automatic condensate evaporator is provided to eliminate the need of floor drains. Automatic condensate evaporator malfunction.
6/13/2015 12:50:05 AM • Beverage-Air... • 190 views • 0 helpful votes
0helpful
2answers

Why doesn't the dehumidifier portion work?

HAVE YOU CHECKED FOR ANY OBSTRUCTION IN THE CONNECTION?
6/20/2015 9:51:52 PM • Beverage-Air... • 92 views • 0 helpful votes
0helpful
1answer

Milk is getting warm. Where is the temperature control?

in diff areas depends on model? see pics 25731045-j0bg5my5wcxq3jsayeotzht3-1-0.jpg 25731045-j0bg5my5wcxq3jsayeotzht3-1-2.jpg 25731045-j0bg5my5wcxq3jsayeotzht3-1-5.jpg 25731045-j0bg5my5wcxq3jsayeotzht3-1-9.jpg 25731045-j0bg5my5wcxq3jsayeotzht3-1-14.jpg 25731045-j0bg5my5wcxq3jsayeotzht3-1-20.jpg 25731045-j0bg5my5wcxq3jsayeotzht3-1-27.jpg
6/5/2015 1:51:41 PM • Beverage-Air... • 103 views • 0 helpful votes
0helpful
1answer

Can i use a beverage air mt27 as a freezer

Nope, You Can not. Compressors for freezers are different and if it set up as an fridge, you will not have enough defrost (on freezers there are heaters)
3/22/2015 11:35:00 AM • Beverage-Air... • 286 views • 0 helpful votes
0helpful
1answer

Should the fawcett parts be leaking?

replace the rubber seal gasket in the hose connector
4/14/2015 4:31:57 PM • Beverage-Air... • 113 views • 0 helpful votes
Not finding what you are looking for?

Ask a Question

Usually answered in minutes!

Top Beverage-Air Experts

Jay Finke
Jay Finke

Level 3 Expert

1397 Answers

ADMIN Andrew
ADMIN Andrew

Level 3 Expert

66967 Answers

Jorgie  the...
Jorgie the...

Level 3 Expert

5639 Answers

Are you a Beverage-Air Expert? Answer questions, earn points and help others

Answer questions

Manuals & User Guides

Loading...