...wire from the blower motor relay to the motor's hi spd terminal. Could you confirm this? are you SURE its 460volt single phase??? that voltage is normally a 3phase motor voltage,and color of wires is ...
...480 to 230/220 3phase all wire number are marked. I can not read 3 of them. 7&4-? 6&9-? 8&5-? this motor is back gauge for a 1808 cininnati shear', built 1956 this motor runs back gauge, ...
Question about Windows XP Professional for PC
...wire 3 phase motor to hi-voltage (480) when the wires coming from the motor are not labeled. You wire it like this: 4 and 7 together 5 and 8 together 6 and 9 together 1 goes to T1 2 goes to T2 3 goes ...
Question about 100 Amp GE Load Center
...wire up a baldor 3 phase motor 208-230/480 15hp and dont have the wiring diagram to know what wire is what or where to hook it to? HVAC 41-38/19 AMPS FRAMe 254T 40C AMB-CONTHVAC Variable Torque Motor ...
Question about 100 Amp GE Load Center
...wire up a 3 phase compresser motor, 9 wires wired 480, to change to 240 volt hookup. right now it is wired 3 motor wires to each hot, no nameplate or wiring diagram. Please verify the existing ...
Question about 100 Amp GE Load Center
...motor shop may be able to reconfigure the generator windings and voltage regulator for your desired 480, the fuses and wiring may also need upgrading to 480 volt compatible. Too much hastle to hack ...
Question about 100 Amp GE Load Center
...480 volt I only have 230 volt 3 phase from a converter. I put 2 starters to match voltage and motor size.what's the prob. talk with an electrician but I think that if you have 3 phase motors on 480 ...
Question about 100 Amp GE Load Center
480 (WG4800 / DVGW A 171 / FD5811) please give me a copy of the schematic diagram or pictures of the motor to capacitor wiring connection to find out color code. Most capacitor start motors have brown
Question about 100 Amp GE Load Center
480 motor from disconnect orange is identified from disconnect to motor brown and yellow are identified on disconnect side not sure witch wire is brown,yellow from the motor does it matter hook it up,
Question about 100 Amp GE Load Center
...motors. if you are trying to tun 480 motor on 240 or 208 there is a wiring plate on motor, perhaps you should not attempt this., you do know that the amperage will increase if you run lower