004-003]. Does the Drum Motor rotate? Yes No Between Drum Motor J210-4 (+) GND (-) Is the voltage +5VDC? Yes No Using the wire network from Chapter 7, check the +5VDC circuits up to Drum Motor J210-4.
...AC Driver PWB. If the fuse is blown, replace it ( PL 9.3). If the fuse blows again, go to the +24 VDC Wirenet and check for a short circuit in the harness. · Open the Drawer and extend it to the ...
Question about WorkCentre XD100 All-In-One Laser Printer
...Roll Solenoid can be heard switching on and switching off. Y N Press the Clear button. There is +24 VDC measured between CN103-1 and GND. Y N Replace the Main PWB PL 7.1. Go to Flag 5 and check the ...
...Figure 1 of this procedure and measure voltage between the Drum Motor P/ J210-4 (+) and GND (-). +5 VDC is measured. Y N Go to Figure 3 of the +5 VDC Wirenets and troubleshoot the problem. Go to ...
transparecy issue +24 VDC power is failed. Status Code 102-319 is displayed after 116-325 is displayed. +24V LVPS is failed. Perform following: Remove Rear Cover (REP 14.2). Remove cover from +24V ...
...If it doesn't then measure voltage between the Drum Motor P/J210-4 (+) and GND (-), it should be +5 VDC is measured. Try measuring the voltage between the Drum Motor. If there is no voltage detected ...
error code 004-341 MCU PWB cannot detect INTLK +5 VDC. Initial Action Check that the Waste Toner Bottle and all four Drum Cartridges are seated correctly. Check fault history for 9-925 faults. If this
...some voltage from the Drum Cartridge Reset Circuit as per below. 2a. If voltage is more than 0.5 VDC measured between PJ CN116-2 and GND then you need to replace the Drum Cartridge Reset Switch PL ...