Questions & Answers for: reverse wire 3 phase

Question about Heating & Cooling

1 Answer

3 phase, motor rotation direction is critical importance. however, it is a simple matter of trial and error if only a fan is involved...not sure of consequences if freon pump is turned backwards...may

Ad

Question about Conveyor Oven - 1133-000-A

2 Answers

...3 phase, just reverse 2 of the 3 motor feed wires. It doesn't matter which 2. If it's single phase, the wiring directions should be inside the motor where the wires go in. reverse a+ and a- on your ...

Ad

Question about Conveyor Oven - 1133-000-A

1 Answer

...3 phase 220vac foward-reverse motor. thank you larry There should be 2 contactors for forward and reverse. you have to wire them so that the power coming in will switch 2 opposite phases to

Question about 115v,1ph, 3,600rpm 7" 1/2hpbnch Grindr W/Exh

1 Answer

...wire is a ground then it goes to the motor frame. if it is a dual voltage motor then here is the wiring: for 240 volt 3 phase connect 4-5-6 together and tape, 3-9 goes on L1, 2-8 together goes on L2, ...

Question about 1 1/2 HP 115/230V 56C Replacement Motor

1 Answer

...reverse rotation on my A.O. Smith 120/230 volt single phase 1.5 HP motor. Catalog number B762 I believe all you have to do is swap your two hot wires,that works for 3-phase but not sure on single ...

Question about 1 1/2 HP 115/230V 56C Replacement Motor

2 Answers

reverse Was the fan motor or fan blade recently replaced? Is the motor a 3 phase motor? If this is a new 3-phase motor you have the phasing incorrect, you need to swap 2 legs of power wiring. If it is

Question about 1 1/2 HP 115/230V 56C Replacement Motor

1 Answer

...wire as well ( which is yellow/ green ) you should reverse either red and yellow position only or yellow and white position only but if in doubt check with your local electrcian to confirm always ...

Question about 1 1/2 HP 115/230V 56C Replacement Motor

1 Answer

...If it is 220 volt,in all probability it is 3 phase. There should be4 wires coming into the saw motor, 1 goes to the ground, the other 3 go to the motor ,reverse any of 2 of the 3 wires. It should ...

Question about 1.5hp Pool Pump Motor Motor A O Smith Electric Pool Motor for 56j Frame Motors Ust1152

1 Answer

...the terminal connection of any 2 of the three phase wires, for example, 1 & 2 or 2 & 3 or 1 & 3, but leaving the third phase wire unchanged will reverse the rotation of most

Question about 1.5hp Pool Pump Motor Motor A O Smith Electric Pool Motor for 56j Frame Motors Ust1152

1 Answer

...3 phase 50A) and see if a color code match can be applied at the welder, although the only issue is whether the wire feed will run forward or reversed. If the wire feed is reversed then move any two ...

Not finding what you are looking for?

Ask a Question

Usually answered in minutes!

Top Heating & Cooling Experts

Paul Carew

Level 3 Expert

3807 Answers

john h

Level 3 Expert

29492 Answers

Brad Brown

Level 3 Expert

19187 Answers

Are you a Heating & Cooling Expert? Answer questions, earn points and help others

Answer questions

Manuals & User Guides

Loading...