...replace the thermistor. Main heater 2) With the fixing assembly removed, is there electrical continuity between connectors J50-3 (FSRN1) and J50-5 (FSRL1) on the fixing assembly side? NO: Replace the ...
Question about (6981A002AA) for imagerunner 2200, 2800, 3300 Print Server
thermistor has a short circuit. Replace the fixing film unit. REF. If the thermistor has a short circuit, the indication in service mode (COPIER>DISPLAY>ANALOG) will be as follows from the start
...thermistor, Replace the fixing unit To recover from the error: In service mode ( * 2 8 * ) COPIER>FUNCTION>CLEAR >ERR 0003 The non-contact thermistor fails to reach 100 deg C within 180 sec ...
Question about iR 2016i Black and White Copier
...Replace the DC controller PCB. E001 0001 Abnormally high temperature (detected by sub thermistor) The sub thermistor detected an abnormally high temperature (295 deg C) during temperature control. - ...
...AC Connector).
- Replace the Fixing Main Thermistor (Film Unit).
- Replace the Fixing Assembly.
- Replace the DC Controller PCB (PCB4).
See Service Manual page 173
...replace the thermistor or the presure stay 4. Disconnection, soiled, improper location of, or faulty pressure sub thermistor -> clean the thermistor or replace it5. Faulty drawer connector -> ...
...2.Check connection of the Connectors (Thermistor Connector and AC Connector). 3.Replace the Fixing Main Thermistor (Film Unit). 4.Replace the Fixing Assembly. 5.Replace the DC Controller PCB
Question about imageRUNNER iR C4080 Color Copier
...thermistor has a short circuit. Replace the fixing film unit. If the thermistor has a short circuit, the indication in service mode (COPIER>DISPLAY>ANALOG) will be as follows from the start: ...
Question about imageRUNNER iR C4080 Color Copier
...thermistor has a short circuit. Replace the fixing film unit. If the thermistor has a short circuit, the indication in service mode (COPIER>DISPLAY>ANALOG) will be as follows from the start: ...
Question about imageRUNNER iR C4080 Color Copier
...thermistor has a short circuit. Replace the fixing film unit. If the thermistor has a short circuit, the indication in service mode (COPIER>DISPLAY>ANALOG) will be as follows from the start: ...