Question about H - Series 400 Heater Top for In - Ground Pools and Spas - Dhi400
...pressure switch operation most heaters will not operate without sufficient water flow/pressure. You can use a multimeter to troubleshoot the wiring using the schematic. If its induced draft milivolt ...
Question about H Series Pool & Spa Heater 400k Btu Propane Gas Milivolt Ignition H400p1
...pressure switch on my customers H250IDL after a repeated AO error code. I went through the service/troubleshoot test modes and the blower seems OK although it does not come on at all. I can hear a ...
Question about 100,000 BTU Pool Heater H100ID1 - Above Ground
pressure switch is a common problem on this model. remove top and its located on top of water inlet header.set meter to "continuity" setting .remove 2 wires to switch and test WITH pump running.as you
Question about H Series Induced Draft Abg 100,000 Heater
...switch, follow the wires, then temp limit switches (2), then air pressure sensor, then to fan & ignition board). I'm betting one of those sensors is bad or sensing something wrong. Do you have ...
...pressure switch to a VIO wire, then through the non-resettable combustion temperature switch to a BLK wire, then through the resettable combustion temperature switch to a PUR wire, than back to the ...
heater wont fire without jumping th terminals went through all troubleshooting something open in safety circuit try pressure switch or copper line