Questions & Answers for: Chevrolet Camaro power relay

Question about 1998 Camaro

1 Answer

the power for the fuel pump directly to power and see if it works if so examine that you have power from the ignition switch and a ground to energize relay and that power is good on feed side of relay

Ad

...power to the relay, there should be power on two of the four legs of the box where the relay fits in. Take the cover off the relay and manually engage the relay. If you have power and at this point ...

Ad

...power on my relay wire from the ignition to the starter If you are not getting power on the relay wire from the ignition switch to the starter solenoid (when the ignition switch is turned to start) ...

...including the one under the hood near the battery area and they are all good and have power? Using a multimeter check the wiring for power at the pump and at the relay. It sounds like a bad

Question about 1996 Camaro

1 Answer

If you have a bad fuse you won't get any power to the relay. If the fuse is good, then you need to trace the wires from the fuse to the relay. You could have a broken wire. It is more likely the fuse

Question about 1991 Camaro

1 Answer

91 camaro carb no power to feul pump, power into relay but not out changed relay still same is there something else activating relay? Give some more details of the problem.

...power to relay port but none back at the pump you need to check the relay for both power on the control side and the switched side you should get a 2 second pulse from the ecm when the key is turned ...

...power to the relay is powered by the PCM BAT fuse 15amp. The relay is grounded and the PCM powers the relay to turn it on and power the pump. You should have power on the orange wire with the key on. ...

power conv.top and windows wont work replaced the fuse , Is there a module A relay chec for power at windo switch if u have power relay is good motor is bad

...power relay that should engage the solenoid when the key is turned. Either the key switch is worn and doesn't energize the relay, or the relay is faulty or sometimes the relay's socket gets corroded ...