Questions & Answers for: LG ls 10

Question about LS-L1210CL Mini Split Air Conditioner

1 Answer

LG Room Air Conditioner Model LSZ182VM-4 Turns on. I set a COOL temp. It displays that temp for about 10 seconds. Then C1 appears instead. Is blowing air....not hot, not cold. Filters just cleaned ...

Ad

Question about LS-K1830CL Cool Mini Split Air Conditioner

1 Answer

water flowing inside the room thru indoor unit drop by drop it flows after 10 minutes from switching on the unit. blocked drain low gas charge cracked drain pan in head unit

Ad

Question about LS-L1210CL Mini Split Air Conditioner

2 Answers

...10-15 minutes. it gets too hot. well fan in outdoor unit keeps on running . when compressor cools down after an hour or so it turns on again and turns off again after 10-15 min. i have replaced ...

Question about LS-L1210CL Mini Split Air Conditioner

2 Answers

Green Light on unit is flashing every 6 seconds We press start and the unit starts up straight away ( always use to take several minutes until the unit started) and stays on for 10 seconds or so then ...

Question about LS-L1210CL Mini Split Air Conditioner

1 Answer

...temperature sensor. But you could have a different issue. I'd have them recheck your freon levels, that can cause it to cool too much - should be 120-135psi when it is running, after 5-10

Question about LS-K1830CL Cool Mini Split Air Conditioner

1 Answer

many VoltAmps does the LG LS-K1830CL consume?, What is the voltage?, Mono or 3 fase?... BTUs: 18,000 (C) SEER: 10 Interior Voltage: 36 Voltage: 208/230 VAC Maximum 8.5 amps Single phase. Is it helpful

Question about LS-L1210CL Mini Split Air Conditioner

1 Answer

pioneer show E7 A/C E-7. This is a communication error between the indoor andout door units.Indoor unit coil sensor fault. Disconnect from PCB measure resistance. 10 kOhm at 10C and 4 kOhm at 30C. if ...

Question about LS-L1210CL Mini Split Air Conditioner

2 Answers

Please help i got a LG r12awn split and the heating light flashes twice followed by one flash on the cooling, ive read through the manual and cant find any thing about it Indoor Pipe Sensor or Outdoor

Question about LS-L1210CL Mini Split Air Conditioner

1 Answer

alaways heat i want toreset the remote TRY SHUTTING THE BREAKER OFF, FOR ABOUT 10 MIN . THERE SHOULD BE A LITTLE HOLE IN YOUR REMOTE , USE A PAPER CLIP TO PUSH IT (LIGHTLY !)THAT WILL RESET THE REMOTE

Question about LS-L1210CL Mini Split Air Conditioner

1 Answer

...LS-L1210 installed back in 2005. The unit powers on, inside fan turns on, outside fan goes on and the compressor starts. Cool air flows out however the unit shuts down after 5-10 min. Did a power ...

Not finding what you are looking for?

Ask a Question

Usually answered in minutes!

Top LG Heating and Cooling Experts

Mike Cairns
Mike Cairns

Level 3 Expert

3054 Answers

MattS1978

Level 1 Expert

7 Answers

Jay Finke
Jay Finke

Level 3 Expert

1397 Answers

Are you a LG Heating and Cooling Expert? Answer questions, earn points and help others

Answer questions