Question about Paslode 901000 Impulse Cordless Finish Nailer

3 Answers

paslode angle finish nailer the fan wont run nor will it shoot have had the same problem! started with a noisy fan then a non responsive one. try taking out the fan assembly as per service and drop a ...

Ad

Question about Trane Furnace Draft Inducer Blower 115 Volt Variable Speed Fasco # A190

2 Answers

I have a Trane Xe-60 furnace about 19 years old. During summer months, with thermostat set to deliver air, the outside condenser runs, but furnace blower does not. I can move thermostat lever from ...

Ad

Question about Trane Furnace Draft Inducer Blower 115 Volt Variable Speed Fasco # A190

2 Answers

The draft inducer comes on and the furnace lites as normanl Goes thru its cycle and kicks off. The problems is the draft may not kick on the next time and sticks and the motor gets hot, If I go remove

Question about Keeprite Furnace Flue Exhaust Venter Blower # Fb RFB350

1 Answer

keeprite furnace will come on heat up but the fan or blower doesn't blow but creat noise. please tell me how can I fix it. Regards Andre Blower motor is either burnt or Ihave also seen the fan relay ...

Question about 5hp 1740RPM 184TC Frame 230 Volts Leeson Electric Motor # 131602

1 Answer

how to conect 3 phase motor 9 yellow wires from p1 how to conect 3 phase motor 9 yellow wires from t1 to t9 Connect t4,t5,t6 together. Connect t1,t7 together for line 1. Connect t2,t8 together for ...

Question about 5hp 1740RPM 184TC Frame 230 Volts Leeson Electric Motor # 131602

1 Answer

how to conect 3 phase motor 9 yellow wires from t1 to t9 Now I know that I supposed to Connect t4,t5,t6 together. Connect t1,t7 together for line 1. Connect t2,t8 together for line 2. Connect t3,t9 ...

Have a Drill Doctor 750X. Will not power up. This is a common problem with these units. How do I troubleshooting the motor, switch, Ect. The wire connections are sealed. My guess is that trash may be ...

Question about 8003 Nutrition Center Juicer

1 Answer

I'll be moving abroad where the power supply is 220V. Would a 200W transformer be good enough to keep Omega 8003 running normally? Thanks for your advice. - Call Omega at 1 800 633 3401 for their ...

Question about Keeprite Furnace Flue Exhaust Venter Blower # Fb RFB350

1 Answer

how do I get the impeller off the motor shaft for the blower on my keep right furnas You don`t. I know it is crazy when the motor is cheap but that is the way they designed it. The inpeller will break

Question about Keeprite Furnace Flue Exhaust Venter Blower # Fb RFB350

1 Answer

The moment it is switched on& a small quantity of vegetables r put in the machine starts vibrating & in another minute starts spinning out of control,it's difficult to hold it down with ...