Questions & Answers for: hpr logic board Ice Cream Makers

Question about 8756-33 Soft Serve Two Flavor Ice Cream Machine

1 Answer

logic board pump comes on builds up pressure to pressure switch and shuts pump off. I can release the line from the pressure swith nipple and water starts flowing (pupm comes back on and will continue

Ad

I have Taylor Ice Cream Machine 754-27 the mix light blinks continuous then beeps and turns off. What is causing this? Troubleshooting help needed most likely a faulty logic board for that side.

Ad

Question about Temporarily Out Of Stock-339-27 Air Cooled Ice Cream & Yogurt

1 Answer

taylor ice cream machine When it starts in the morning the ice cream is firm but as the day goes on the ice cream starts to soften??? might have to adjust the cycle timers on the logic boards

Question about Temporarily Out Of Stock-339-27 Air Cooled Ice Cream & Yogurt

1 Answer

...logic board. The product in the cylinders should go back to liquid form in standby, but we still have to maintain that safe food temperature, the motor and compressor will run periodically. If the ...

Question about Temporarily Out Of Stock-339-27 Air Cooled Ice Cream & Yogurt

1 Answer

default to the logic board. Is there a standard default setting? Generally, its user's preference, but I usually set the DIP switches to 1, 5, and 7 in the on position and the rest in the off position

Question about Temporarily Out Of Stock-339-27 Air Cooled Ice Cream & Yogurt

1 Answer

logic board X36641SER2Refurbished Gen 2 Logic Board This item is sold with exchange...measures the viscosity of the product by monitoring the amp draw of the beater motor. When the machine reaches the

...logic board. Since the left and right side logic boards are the same, you could swap the two boards and see if the issue follows the board.

Most people will order the logic board and replace ...

Question about Temporarily Out Of Stock-339-27 Air Cooled Ice Cream & Yogurt

1 Answer

WHAT IT MEANS R-HPR THERMAL FAIL FOR TAYLOR ICE CREAM MACHINE MODEL C713 That code means the right side hopper thermistor probe has failed. That is the sensor that reads the temperature of product in ...

Brush Cleaning did not clear the (L / R) HPR> 45F (7C) AFTER 1 HR fault on my Taylor Model C723 soft serve ice cream freezer. Certain conditions must be met. The machine needs to be empty. The freezer

...Logic Board on left side, also replaced ribbon cable Have your electrical panel on the bottom open. While listening to the left hand power board, turn the left hand logic board mix potentiometer all ...