Question about XHB123D X/Y Series Heat/Cool Air Conditioner
...heat pump has died (what happened to me) or the relay for that fan has gone bad. Either way you will need an A/C tech to diagnose it with a multi-meter. FYI even with warranty (on the fan part) it ...
Question about XHB123D X/Y Series Heat/Cool Air Conditioner
...heat pump you can switch to heat and see if coil outside gets cold while indoor blows warm air - then switch back to a/c - both coils should not be cold at the same time - low freon pressure / dirty ...
Question about XHB123D X/Y Series Heat/Cool Air Conditioner
my a/c works but the heat side only blows cold my a/c works but the heat side only blows cold air check the heater element
...blows cold air a/c works heating blows cold air Is this an electric unit? I guess it is. It appears tha the heating elements are not activating. Check to see if the contactor pulled in on a call for ...
Question about XHB123D X/Y Series Heat/Cool Air Conditioner
...heat pump does not come on. can go to e-heating and furnace works fine. no fuses on heat pump, no reset button and circuit breaker is fine. believe this is electrical, not mechanical. thanks ...
...heat pump. The main breaker keeps tripping because the compressor is shorted. I hate to give you this news, but anytime a unit keeps tripping the main breaker on a heat pump, the compressor is either ...
Question about XHB123D X/Y Series Heat/Cool Air Conditioner
...cold air for heat the air conditioner is working fine but the heater is blowing out cold air Hi, it sounds to me like your reversing valve is not switching the flow of freon over to heat, stuck in ...
Question about Payne 2.5 Ton Air Conditioner Compressor And Evaporator R-22 Used
conditioner blowing warm inside and cold outside it's a heat pump in the heat position . Check the thermostat to see if it's in the heat position. If not then the changeover valve on the unit is stuck
Question about Payne 2.5 Ton Air Conditioner Compressor And Evaporator R-22 Used
...heat pump setting check the thermostat also check the inline fuse for the electric heat coil . check wires in control panel they tend to burn and last check to make sure reversing valve is changing ...
Question about Payne 2.5 Ton Air Conditioner Compressor And Evaporator R-22 Used
...unit have a heat pump --heat pump w/emergency heat---environmental set up etc ---if you have old stat look up online for wire install guide for it --because it sounds like unit is in heat pump ...