Questions & Answers for: Lutron ground

Question about Toggler Single Pole 600 Watt Preset Dimmer With Nightlight - White

1 Answer

continuous ground wire problem How do I thread/wind the ground wire if it is continuous and connects to two switches? Can't wind the ground wire around anything using the area provided...thanks What ...

Ad

Question about #D-600PH-DK 600W SP Push Rotating Dimmer

1 Answer

no ground wire on the dimmer switch what do I do with the ground wire coming from the box Place it under the mounting plate where the 2 mounting screws mount to the wall box.

Ad

Question about LG-600P Lumea Single-pole 600 Watts Incandescent Dimmer

1 Answer

it? In household wiring (AC) there is really no positive and negative, they are hot and neutral and ground. Wire black to black, yes. But the green one is the ground and if you wire this one wrong you

Question about LG-600P Lumea Single-pole 600 Watts Incandescent Dimmer

1 Answer

First, I have power running thru a switch box. All white commons are tied together. Then I tap power to S1 switch leg with light working normal using a standard S1 switch. Then using a Lutron DV-600P ...

Question about #D-600PH-DK 600W SP Push Rotating Dimmer

2 Answers

i AM REPLACING A LUTRON DIMMER SWITCH AND HAVE i THINK MADE ALL THE RIGHT CI=CONNECTIONS - COULD A FAULTY GROUNDING BE THE PROBLEM? As a general rule, grounding will not affect operation of dimmer. ...

Question about S-603PG Skylark Single Pole/3-Way 600 Watt Incandescent Preset Dimme

1 Answer

...Twist a wire nut over this wire for a single-pole application. 2) Green wire connects to bare ground wire. Or bare ground to bare ground. 3) Connect dimmer-red and dimmer-black to either ...

Question about S-603PG Skylark Single Pole/3-Way 600 Watt Incandescent Preset Dimme

1 Answer

REPLACEMENT OF PRIOR DIMMER The dimmer I'm replacing hS NO GROUNDING (GREEN) WIRE. WHAT DO I DO WITH THE GREEN WIRE THAT COMES WITH THE NEW DIMMER? All ground wires should be connected ...

Question about Dimmers S2LFSQ Dual 1.5A Quiet Fan and 300W Light Dimmer White Skyla

1 Answer

...switch which had nothing going to. I ran black power supply to base supply, yellow to fan black, ground to ground, tied commons together, cant get it to work. I doubt it. They are designed for a 3 ...

Question about Dimmers S2LFSQ Dual 1.5A Quiet Fan and 300W Light Dimmer White Skyla

1 Answer

may i use a ground wire instead of neutral On single-phase wiring systems, the neutral and ground wires are connected to the same bus bar in the circuit breaker panel (thus they are the same potential

...coming out of old switch and connect with wire nuts to black wires of new switch? And cap off the ground wire from new switch since no ground on old switch? Replacing Thyrocon SDP600 single pole ...

Not finding what you are looking for?

Ask a Question

Usually answered in minutes!

Top Lutron Electrical Supply Experts

Brad Brown

Level 3 Expert

19187 Answers

ADMIN Andrew
ADMIN Andrew

Level 3 Expert

66957 Answers

Eric Kalman
Eric Kalman

Level 1 Expert

13 Answers

Are you a Lutron Electrical Supply Expert? Answer questions, earn points and help others

Answer questions

Manuals & User Guides

Loading...