Questions & Answers for: Friedrich freon coming vents

Question about M18CF Split System Air Conditioner

3 Answers

...what would cause such a problem and potential solutions? Thank you. Hi, Reduced air flow, low on freon or being continuously run during cooler weather such as at night. Some people turn their ...

Ad

Question about QuietMaster RS10J10 Air Conditioner

1 Answer

...coming out of the vents are cold. I cleaned the filter and made sure the vent is closed, but it still does not cool the room. I noticed that only the coils in the bottom half of the unit are chilled ...

Ad

Question about M18CF Split System Air Conditioner

1 Answer

...into the bottom of the pan from the rear for better drainage and I knicked the back coils. all the freon escaped;how can it be fixed inexpensively and can i buy the freon from commercial source like ...

Question about CP12C10 Wall/Window Air Conditioner

1 Answer

Friedrich AC through the wall ac leaking water out front vent Just purchased new Quietmaster. Works great but water(condensation)is coming out the front vent. It's installed through the wall and the ...

Question about QuietMaster Electronic SS12J30D Air Conditioner

1 Answer

Some air comes out of the vents around the house, but the air is not cool. The circuit breaker in the basement is in the off position and will not return to the on position. Sounds like an electrical ...

Question about QuietMaster RS10J10 Air Conditioner

1 Answer

where is the vent on my Friedrich AC unit? I don't know how to close or open it. the fresh air vent open close tab should be located somewhere along the vent louvers look at the bottem of them ...

Question about QuietMaster SL28J30A Air Conditioner

1 Answer

Coil freezes up even on low cool..room does not get cool dirty coils or low freon: clean coils off and out, they sell coil cleaner in a spray can, as far as needing charged, you will have to find a ...

Question about YS12M33 12100 BTU ThruWallWindow Air Conditioner

1 Answer

...vents. The air coming out of it was not very cool even when lowering the thermostat. I turned it off and cleaned the filter which was very dirty. I put it back it and turned it on and it worked fine. ...

Question about QuietMaster KM18L30 Wall/Window Air Conditioner

1 Answer

How do i recharge freon for me Friedrich KM18J30A-3 window unit? Everything else seems to work, just blowing hot air. So I believe it is a freon issue. Compressor seems to work fine. How would I ...

...to have a short duty-cycle. Not sure if this would be indicative of a malfunction or what. low Freon will cause the compressor to short cycle window units will give you an approximate 15 to 20 ...

Not finding what you are looking for?

Ask a Question

Usually answered in minutes!

Top Friedrich Heating and Cooling Experts

john h

Level 3 Expert

29494 Answers

Jay Finke
Jay Finke

Level 3 Expert

1397 Answers

ADMIN Andrew
ADMIN Andrew

Level 3 Expert

66963 Answers

Are you a Friedrich Heating and Cooling Expert? Answer questions, earn points and help others

Answer questions

Manuals & User Guides

Loading...