SC 548 Fuser installation error. Fusing unit set error. Remove the fusing unit out of the machine and reinsert it. It isn't seated in there properly. Once you do that the error code will go away. Note

Ad

Question about Aficio 1022 All-In-One Laser Printer

5 Answers

SC-546 is "Warm-up" error, suggests that the fuser is NOT reaching 160' within standard warmup time. You might be able to take out the fuser, remove fuser cover, remove carbon buildup from thermistor.

Ad

Question about Aficio 1035 Copier

3 Answers

...sc 546 problem Fuser warm up error. Fusing ready temperature unstable The fusing temperature is fluctuating. Thermistor connection loose Fusing unit connector loose try clean or changing the ...

SC-546 is "Warm-up" error, suggests that the fuser is NOT reaching 160' within standard warmup time. Hangs, and does NOT go to ready state. 1. Remove fuser cover, remove carbon buildup from thermistor

Question about Aficio 450 Copier

2 Answers

...Error Code SC 546 is for fusing & SC 960 is for Current leakage, If u getting it regurally , change the thermistors for error code 546, & for error 960 change drum & charge roller. If ...

...SC 546 are fuser temperatyre error. pls. check thetmistor/ thermostats, connectors if thernistor are deffective replace thermistors. after replacement or checking of this parts do the SC reset. 107 # ...

Question about Aficio 1035 Copier

1 Answer

Savin 8025 SC-546 error message you have an over heat error. you need to test your thermistors, s and lamps for continuity.replace bad parts. then you need to go to service mode and reset the code

Question about Aficio 1035 Copier

1 Answer

...fix a SC- 546 error on my NASHUA Aficio 2018D all in one problem You could try to reset the error, but it may come back. Here is the key sequence for resetting: CLEAR MODES 10 7STOP (hold down for ...

...error. It does the same thing if I print using the feeder or trays. SC 546 - Fusing ready temperature malfunction,unstable fusing temperature.Chek the fuser unit upper fuser roller thermistors,if ...

Question about AFICIO SP4100NL MONO-LASERPR 31PPM USB2.0 Printer

1 Answer

error codes in order to alert users that there is a problem with the functioning of the copier. Codes that begin with "SC" refer to issues with the fuser components, which heat up to bind the toner or

Not finding what you are looking for?

Ask a Question

Usually answered in minutes!

Top Office Equipment & Supplies Experts

k24674

Level 3 Expert

8093 Answers

Brad Brown

Level 3 Expert

19187 Answers

ADMIN Andrew
ADMIN Andrew

Level 3 Expert

66831 Answers

Are you an Office Equipment & Supplies Expert? Answer questions, earn points and help others

Answer questions

Manuals & User Guides

Loading...