Question about CW-C60RU Air Conditioner
...can the air con be activated again. Check that your water pump is working and not blocked up as the unit will keep swicthing off if it can not get rid of the water. midea air conditioner caset error ...
Question about Room Air Conditioner CWXC104HU
...error code H16 in a Panasonic air conditioner CS-E12EKK / CU-E12EKK end i want check and I would like tested with a tester the part corresponding to this code Thank You By Advance Ben Hello, I have a ...
air conditioner CS-E24GKR...The unit stops and the timer indicator blinks. Also displays error code H 11...Help...Please...its hot in here H-11Indoor / outdoor abnormal communication. Check • Internal
...error E2 E2Fault indoor coil out sensor. Indoor Pipe Sensor or Outdoor Sensor Assy fault, Open or Short. Disconnect from PCB and measure resistance. Air sensor = 10 kOhm at 25C, Pipe sensor = 5 kOhm ...
...error code of an air conditioner panasonic s91 inverter.Grazie Grazie, your question is rather confusing, because you listed to different model numbers for to different types of appliances. The ...
air conditioner model CU-E12EKU (inverter). The unit stop working and the timer indicator is blinking. I checked for this error and followed the instructions in the Operating Manual, page 4. The error
Question about CS-S12NKUA 12,000 BTU Low Ambient Air Ductless Mini-Split Wall-Mounted Cool Only Air Conditioner Indoor Unit
error code F95 cool high rise protection i have this problem... and after own troubleshooting with rc found this error - F95.. detects the outdoor pipe temp and compressor stop if temp exceed 63deg C.
Question about CS-S12NKUA 12,000 BTU Low Ambient Air Ductless Mini-Split Wall-Mounted Cool Only Air Conditioner Indoor Unit
panasonic ag 7500 tape will not eject error message E2 E2 is a front motor loading lock error code,needs to be looked at.
Question about CS-S9NKUA Ductless Mini Split Wal Cool Air Conditioner
air conditioner css9nkua error code h99 what does it mean need meaning of error code h99 12.11 Freeze Prevention Control 2 • Control start conditions o During Cooling operation and soft dry operation
Usually answered in minutes!
35 Questions
26 Questions
18 Questions
21 Questions