...clean out the idc sensors imgae density control sensors Also there is firmware to correct the issue do this last the above will get rid of your issuesAlso add toner to all the units manually add the ...
...2554 C - 2554 Abnormally high toner density detected magenta TCR sensor. Clean the TCR sensor window on the underside of the imaging unit,reinstall imaging unit if neccessary change the imaging
Question about Konica Kit For Bizhub Press C7000 350k And C6000 300k Dadupm3500
error code c2801 Maximum density correction problem.Clean the AIDC sensor located under OPC drum.
...bizhub c253? C 2554 Abnormally high toner density detected Magenta TCR sensor. Clean the TCR sensor window on the underside of the imaging unit if dirty,reinstall imaging unit or change imaging
Question about Bizhub 600 750 Image Control Board 57aa-9016g
...clean the sensor with white cover or the clear cover clear cover is for paper jams the white cover monitors the toner density on the drum. The Sensors are mounted on a circuit board the board may be ...
...it will see a silver/chrome 1/4" near the front with very small square hole, inside that hole is a sensor that reads the drum density for that color, But first clean the sensor with a clean
Question about Bizhub Press C6000 Copier
density is low. 2 Clean the TCR sensor window on the underside of the imaging unit if dirty 3 Reinstall imaging unit. 4 Reinstall toner cartridge. 5 M9, M10, M11 operation check (At this time, IU must
...Clean IDC sensors that read toner density on transfer belt. And do Image stabilise reset. If that doesn't help then: If Imaging units are over life -replace them if Transfer belt is over life replace ...
Question about Bizhub Press C6000 Copier
...Density Control abnormality in Developer. Try in this sequence.. 1-Check Toner, if Empty, Reset code and install new toner bottle. 2- if not from above, Then replace Developer and Developing ...
Question about Bizhub Press C6000 Copier
density is low. 2 Clean the TCR Sensor window on the underside of the Imaging Unit if dirty. 3 M6, M7 operation check PWB-M CNDM2-10 to 13 (M6) PWB-M CNDM3-10 to 13 (M7) C-20 C-21. 4 Reinstall Imaging