Question about Corrosion Resistant Shallow Well Jet Pump 1/2HP, 8GPM
...stuck in there. Then prime and leave the pressure pipe closest to the outlet slightly loose to let air out. Once you get good pressure you can tighten the pipe. Sometimes you have to prime more than ...
Question about Corrosion Resistant Shallow Well Jet Pump 1/2HP, 8GPM
...32lbs pressure tank is in house 75 ft from well pit where pump&pressure switch are located 28lbs of air in tank sometimes pump turns on &right off when no water is being drawn Look for a place in the ...
air in lines I have a 1/2 horse pump and a 30 gal bladdered holding tank. Just redrove a point 12 1/2 feet from basement floor. water is sitting in 1 1/4 pipe 6 1/2 feet down. I have a check valve on ...
I have a problem with my waterwell. It keeps getting air in the line. What is wrong? Your well may be low or you may have a crack in your pipe so when it is off water can drain down in the pipe and ...
...see anything, It is possible the pump seal is beginning to leak slightly when it's off, allowing air to enter the system. You could add another check valve near the pump, but it isn't necessary if ...
...pipe of the pump. I always do this when installing a new pump, because sometimes the pump will get air in it, the little hole will vent out the air. There will be water squirting out the little
...discharges to. The weep hole needs to be below the check valve. The hole is there to prevent an air lock in the pump which would prevent it from moving water. If the water trapped in the vertical ...
Question about Corrosion Resistant Shallow Well Jet Pump 1/2HP, 8GPM
...small impeller housing edge break I can see no reason for no suction????? Hi jandh40... You have an air leak somewhere in your piping, housing of the pump or maybe the mechanical seal and that is ...
I have a .5 horse flotec jet pump that started running excessively today. I noticed a small air lead at the discharge piping, so I replumbed the discharge. This did not fix the problem. My pressure ...
Question about Corrosion Resistant Shallow Well Jet Pump 1/2HP, 8GPM
...system water pressure. If the unit didn't pull water from the well, check the piping for air leaks. See the full trouble-shooting guide in the manual. Page 9 has the priming information