Vt575 pROJECTOR Hi I am getting a message to replace or clean the filter, where could I get a new one

  • Anonymous Jun 18, 2012

    You not need replace new filter all you can do get the NEC VT460 remote control enter main menu then go to default look at on right you will see All Data then go to Clean Filter Usage hit ok, Your problem should be shorted out Have nice day or night all.

×

3 Answers

Anonymous

Level 1:

An expert who has achieved level 1.

New Friend:

An expert that has 1 follower.

  • Contributor 1 Answer
  • Posted on Jun 18, 2012
Anonymous
Contributor
Level 1:

An expert who has achieved level 1.

New Friend:

An expert that has 1 follower.

Joined: Jun 18, 2012
Answers
1
Questions
0
Helped
269
Points
1

You not need replace new filter all you can do get the NEC VT460 remote control enter main menu then go to default look at on right you will see All Data then go to Clean All Data hit ok, Your problem should be shorted out Have nice day or night all.

Anonymous

Level 1:

An expert who has achieved level 1.

  • Contributor 1 Answer
  • Posted on Sep 25, 2008
Anonymous
Contributor
Level 1:

An expert who has achieved level 1.

Joined: Sep 25, 2008
Answers
1
Questions
1
Helped
269
Points
1

How do pop out the filter to clean it?

Ad

Steve Rand

Level 2:

An expert who has achieved level 2 by getting 100 points

All-Star:

An expert that got 10 achievements.

MVP:

An expert that got 5 achievements.

Novelist:

An expert who has written 50 answers of more than 400 characters.

  • Expert 210 Answers
  • Posted on Aug 20, 2008
Steve Rand
Expert
Level 2:

An expert who has achieved level 2 by getting 100 points

All-Star:

An expert that got 10 achievements.

MVP:

An expert that got 5 achievements.

Novelist:

An expert who has written 50 answers of more than 400 characters.

Joined: Aug 20, 2008
Answers
210
Questions
0
Helped
45063
Points
458

My VT440 says this when it gets to it's pre-defined service life. (a certain amount of hours)

As long as you pop the filters out regularly and clean them (I use a vacuum cleaner) you shouldn't need to replace them.

After that, go into the projector options (with the remote control) and reset the factory defaults... otherwise it has no idea that you have actually changed the darn thing and keeps complaining no matter what! =-]

Add Your Answer

×

Uploading: 0%

my-video-file.mp4

Complete. Click "Add" to insert your video. Add

×

Loading...
Loading...

Related Questions:

0helpful
1answer

Turn off on screen message

follow this steps and fix it. God bless you

  • Secure the lamp cover and the air filter cover of the projector body if the projector does not power on. Ensure that the power cable is firmly connected to the projector and an active power plug. If the projector was turned off and then on quickly--let it sit for 90 seconds before trying to turn it on.

  • 2
    Replace the projection lamp if the projector will not power on or if the lamp indicator is flashing. Turn off the projector and let it sit for at least 30 minutes. Locate the lamp cover and remove or loosen the lamp cover with a screwdriver. Carefully remove the projection lamp from the projector housing using the handle, if available.

  • 3
    Place the new projection lamp into the projector housing and secure it to the projector. Replace the lamp cover and reset the lamp timer. Power on the projector to ensure the new lamp is working correctly.

  • 4
    Remove the projector from the enclosed area to allow air circulation if it constantly overheats. Place the projector into an open area and make sure there is no blockage for the ventilation holes. Unplug the projector for at least 45 minutes to allow it to soft reset.

  • 5
    Clean the air filter to allow the projector better air circulation. Turn off the projector and unplug it from the outlet. Remove the air filter cover and use a vacuum to remove dust from the area. If the filter is unable to be cleaned correctly or is damaged, then replace it. Pull the air filter from the projector and place the new one in the now empty slot. Close and secure the air filter cover.

0helpful
1answer

No red in picture but red lines on screen

Not familiar with this projector, is it 3 CCD? if not, it might be using a color wheel and from the sound of it the red is broken off...
Tony

Btw, I’m available to help over the phone in case u need at https://www.6ya.com/expert/tony_a41fa0b801734e2f

0helpful
1answer

Panasonic projector dust filter warning

you need to clean dust filter and replace filter if required
it depends on which model u are referring to
this message is seen generally in the hi end models only - DLP range in access of 4000 lumens
1helpful
1answer

How do i access the air filter on the PJ551?

Air-Filter
Cleaning the Air Filter
The air filter should be cleaned as described below at intervals of approximately 100 hours. When
the filter is used for approximately 100 hours, the message "CLEAN THE AIR FILTER" appears
when the projector is switched on.
1 Switch the projector power supply OFF, and remove the power cord from the power outlet.
2 Clean the air filter with a vacuum cleaner.
3 Reset the Filter Timer using the function of the FILTER TIME on the OPTION Menu. Please
refer to the description of the "FILTER TIME" on the Table 9: MAIN Menu.
Replacing the Air Filter
Replace the air filter if contamination cannot be removed, or if it is damaged. To order a new air
filter see page 26 for contact information.
1 Switch the projector power OFF, and remove the power cord from the power outlet.
2 Remove the filter cover and the filter.
3 Replace the new air-filter and the filter cover.
4 Reset the Filter Timer using the function of the FILTER TIME on the OPTION Menu. Refer to
the description of the "FILTER TIME" on Table 9: MAIN Menu.
4helpful
1answer

After turning on the projector, I get a message that says clean the filter and reset the timer. How do I do that? I have cleaned the filter.

Procedure for resetting filter time.
Pressing the RESET button for about 3 seconds displays the FILTER TIME menu. Select the RESET using button to reset the timer. : RESET <- CANCEL Selecting the RESET resets the count of the lamp timer to 0. memo Perform this function only when you have cleaned or replaced the air filter. The filter timer counts the used time of the air filter after cleaning or replacement, to display the messages about the air filter. Incorrect performing causes incorrect operation of the messages. memo About caring for the air filter, please refer to the section "Air Filter".
Users manual located here. http://www.aboutprojectors.com/pdf/hitachi-cp-x1250-manual.pdf
Good info deserves a good thumbs up! Thank you!
0helpful
1answer

How do I change the filter on my CP S335 projector. It is saying no air flow.

WARNING ?Before caring, make sure the power switch is off and the
power cable is not plugged in, then allow the projector to cool sufficiently. The
care in a high temperature state of the projector could cause a burn and/or
malfunction to the projector.
?Use only the air filter of the specified type. Do not use the projector with the
air filter and filter cover removed.
?Avoid wetting the projector or inserting liquids in the projector. It could result
in a fire, an electric shock, and and/or malfunction to the projector.
CAUTION ?Please replace the air filter when it is damaged or too soiled,
and also when you replace the lamp.When the indicators or a message prompts you to clean the air filter, clean the air filter as soon as possible. If the air filter becomes clogged by dust or the like, internal temperatures rise and the power may be automatically turned off for malfunction prevention.
1. Turn the projector off, and unplug the power cord. Allow the projector to cool for at least 45 minutes and prepare a vacuum cleaner.
2. After making sure that the projector is cool adequately, slowly turn the projector so that the lens-side is facing up. Please be careful for a projector not to fall. While the projector is placed lens-side up, hold the projector.
3. Putting a finger on the filter cover's knob, slide the filter cover in the direction of the arrow to remove it.
4. Holding the air filter's knob, pull the air filter off.
5. Apply a vacuum cleaner to the vent of the projector for the air filter. And then slowly turn the projector bottom up.
6. Apply a vacuum cleaner to the air filter and filter cover.
Please replace the air filter when it is damaged or too soiled.
To prepare a new air filter, contact your dealer and tell the air filter type number = NJ09702.
An air filter of specified type will come even with the replacement lamp for this projector.
7. Position the cleaned air filter or a new air filter into place, and push the points
of "PUSH" word with claws to fix the air filter.
8. Replace the filter cover and snap it back into place.
9. Slowly turn the projector so that the top is facing up.
10. Turn the projector on, and reset the filter time using the FILTER TIME
function of OPTION menu (?37).
NOTE • Incorrectly resetting of the filter timer (resetting without replacement,
or neglect of resetting after replacement) will result in incorrect message
functions.
0helpful
1answer

The nec vt575 shows an image on the projector but not from laptop

this is very simple, its just a matter of a bios upgrade for your laptop
2helpful
1answer

How we can clean airfilter because message is appearing regarding clean your air filter

check in the menu to see if there is a filter timer that you can reset. if so, reset it. if not, there is an air flow sensor on the projector that will send that message if the air flow is decreased so the projector does not overheat. find the filter and remove it. blow it out with canned air and blow out the projector as well. replace the filter and enjoy!
0helpful
2answers

Svideo and component video inputs

You mustn't have them plugged in. So try pulling them out then plugging them in. If this doesn't work you will probably need new cords. When buying the cords keep receipt in case you need to get a refund because it was'nt the problem. Also make sure they are plugged inthe right spot!

Hope this helps - Josh

NOTE : PLEASE GIVE FEEDBACK If you don't in seven days it will be presumed i fixed the problems.
5helpful
1answer

Projector Reset

Hi Here is the info for you :: Caring For The Air Filter The air filter should be cleaned about every 100 hours. If the indicators or a message prompts you to clean the air filter, clean the air filter as soon as possible. If the soiling will not come off the air filter, or it becomes damaged, then it needs to be replaced. Please replace the air filter as soon as possible. memoWhen you replace the lamp, please replace also the air filter. Turn off the projector, and unplug the power cord. Allow the lamp bulb to cool for at least 45 minutes. Apply a vacuum cleaner to the top of the filter cover and the air filter to clean. If the soiling will not come off the air filter, or it becomes damaged, it needs to be replaced. If the air filter needs to be replaced, contact your dealer to prepare a new air filter. Tell the dealer your air filter type. Turn on the projector power, and reset the filter timer. (1) While the projector running, press the MENU button to open the menu. (2) Choose the ?OPTION? on the menu using the / button, then press the button or ENTER button. (3) Choose the ?FILTER TIME? using the / button, then press and hold theRESET button for 3 seconds. (4) Choose the ?RESET? using the button. memo Incorrectly resetting of the filter timer (resetting without replacement, or neglect of resetting after replacement) will result in incorrect message functions. Here is the link to the users manual :: http://www.aboutprojectors.com/Hitachi-CP-X1250-projector.html Further Questions ?? Email Me [email protected] Have a great evening.
Not finding what you are looking for?

279 views

Ask a Question

Usually answered in minutes!

Top NEC Office Equipment & Supplies Experts

Alexander

Level 2 Expert

171 Answers

ExpressFiX
ExpressFiX

Level 2 Expert

691 Answers

Grand Canyon Tech
Grand Canyon Tech

Level 3 Expert

3867 Answers

Are you a NEC Office Equipment and Supply Expert? Answer questions, earn points and help others

Answer questions

Manuals & User Guides

Loading...