Viking VWH3048 Kitchen Hood Logo
Posted on Aug 19, 2008
Answered by a Fixya Expert

Trustworthy Expert Solutions

At Fixya.com, our trusted experts are meticulously vetted and possess extensive experience in their respective fields. Backed by a community of knowledgeable professionals, our platform ensures that the solutions provided are thoroughly researched and validated.

View Our Top Experts

Brand new Viking 3048SS hood - fan switch not working

Followed instruction & installed brand new Viking 3048SS range hood. All switches work except fan switch. When plugged fan directly to outlet, it worked. The exterior fan was installed on roof with 10in duct work to hood. Called Viking. Authorized Viking tech came to inspect and suggested installation is incorrect. (charged about $200 for a 5min inspection!) Hired an electrican to re-install. Same problem. Suggested switch is bad. Need help here!

  • 2 more comments 
  • deekman Aug 24, 2008

    Thanks very much for your response! I'll hold ground & continue to inquire Viking. Will let you know outcome.

  • Helen McDonald
    Helen McDonald Mar 11, 2014

    Just had an electrician look at our VWH3048 range hood. I had turned on fan and it was not working. Lights were all working. Tested motor on separate outlet and it works. He popped out the one inch fan rocker switch and tested it and it was good. He could not get a test on the wires that had been connected to the switch. Process of elimination seemed to put the problem onto the part that controls the motor fan speed. He ran out of time and was to come back and remove that other part since it was going to be more than a quick pop out. At my behest he plugged everything back in and I asked that he make sure that switch was really plugged in well to those tow wires. He then turned everything back on. Out of curiosity, I flipped the switch. The fan and the motor speed control both work. This is an electrician friend and was free. For now we do not need a part. If it happens again, we will check for othr loose wires. This range hood, also, had the capacitor replaced a year ago and that was a $7.00 item. Viking wanted to sell me a new motor.

  • Helen McDonald
    Helen McDonald Mar 11, 2014

    Above I was referring to those two wires that look blue and orange/pink.

  • Anonymous Mar 25, 2014

    dirty fans

×

1 Answer

Anonymous

Level 2:

An expert who has achieved level 2 by getting 100 points

Hot-Shot:

An expert who has answered 20 questions.

Corporal:

An expert that hasĀ over 10 points.

Mayor:

An expert whose answer gotĀ voted for 2 times.

  • Expert 89 Answers
  • Posted on Aug 23, 2008
Anonymous
Expert
Level 2:

An expert who has achieved level 2 by getting 100 points

Hot-Shot:

An expert who has answered 20 questions.

Corporal:

An expert that hasĀ over 10 points.

Mayor:

An expert whose answer gotĀ voted for 2 times.

Joined: Aug 20, 2008
Answers
89
Questions
0
Helped
43135
Points
218

Think i would call viking back and ask for refund of inspection fee and go by the bad switch scenerio the electrician said new fan that would be considered flaws in workmanship in most states dont know where you are located but pretty much same anywhere most inspectors for these companies always try to blame problems off on installers hold your ground and make them fix it and refund that" inspection " fee I've been doing electrical work for several (20+) years it takes longer than 5 minutes to troubleshoot something like that good luck

Add Your Answer

×

Uploading: 0%

my-video-file.mp4

Complete. Click "Add" to insert your video. Add

×

Loading...
Loading...

Related Questions:

0helpful
1answer

Viking range hood dimmer switch

Sorry we have no part locating services here at this website.
0helpful
1answer

I have a viking range hood and the blower has stopped working. the motor hums when the switch is on but no longer runs the exhaust fan. I plugged it directly in to test if the switch was the issue and it...

Had same problem with the Viking PV300001. Motor would hum but did not spin. Fixed it by changing the 5uf capacitor, which required removing the motor/fan assembly (loosen one wingnut + two barrel nuts)
1helpful
2answers

Exhaust fan and lights do not work

see this steps and fix it. God bless you
Switch If the range vent hood fan and light are not working the switch might be defective. Watch our video on switch testing and test this switch for continuity.

Selector Switch If the range vent hood fan and light are not working the selector switch might be defective. Watch our video on switch testing and test this switch for continuity.

Rotary Switch If the range vent hood fan and light are not working the rotary switch might be defective. Watch our video on switch testing and test this switch for continuity.

Rocker Switch If the range vent hood fan and light are not working the rocker switch might be defective. Watch our video on switch testing and test this switch for continuity.

Switch Kit If the range vent hood fan and light are not working the switch kit might be defective. Watch our video on switch testing and test this switch for continuity.

Micro Switch If the range vent hood fan and light are not working the micro switch might not have continuity. The best way to test the switch is with an Ohm meter. See our switch testing videos for help testing this micro switch.

Thermal Fuse If the range vent hood fan and light are not working the thermal fuse may have blown. It can be tested for continuity. Watch our fuse testing video for more information.

Main Control Board If the range vent hood fan and light are not working the main control board may be defective.

User Control and Display Board If the range vent hood fan and light are not working the user control and display board may be defective. Check other causes before ordering this board.
0helpful
1answer

Takes forever for my oven to preheat to 400*. 25 minutes or so. Oven is brand new.

A brand new oven should work. You should not tinker with a brand new oven. A brand new oven that is malfunctioning is probably under warranty and should be repaired under that warranty.

Viking is the Rolls Royce of kitchen equipment. Call your installer or builder or Viking for service for your brand new oven.

Thanks for your question @ FixYa.com
4helpful
2answers

Fan stays on long after oven is shut off in brand new viking daul fuel range. It's been on now for 45 minutes. All controls are on OFF.

loads of ovens do this. It's a pain, especially if you eat in the kitchen. If you switch the appliance off and on at the wall it usually stops it. Why the fan stays on, god knows. pointless.
0helpful
1answer

30" viking downdraft goes up & down fan runs and will not responed when pushing on touch panel

After 11 years of use, the same problem just happen a few days ago - fan keeps running, doesn't respond to the on/off switch. Also cannot reset filter alert. As far as I can tell the entire switch panel isn't working. Or worse, shorted out. Might have to replace the ribbon and some switches.
For example the switches can be found at AllVikingParts.com For example --> http://www.allvikingparts.com/Button_Switch_Assy_p/pv300182.htm
There's a another thread on this forum: http://www.fixya.com/support/t410261-viking_downdraft_ventilator_electrical
I'll post the exact solution as soon as I have it figured out completely.
0helpful
1answer

My Hygena cooker hood fan (model APP2540) stopped working.

this sound like the pcb for all your cooker hood spares visit our site

You-Tube video "8eLuShj-RAg" placeholder (do not delete)
0helpful
1answer

Range hood light switch not working.

you have checked the bulb? if so the the switch of disconnect from supply first and have a look at the condition of the switch it might be full of goo. joe
7helpful
3answers

Viking hood light went out . new bulbs . did not fix it

the dimmer switch/thermostat is most likely bad. resistor inside is burned.p/n pe050033  you can change it yourself with a little mechanical aptitude.
0helpful
2answers

Fan switch not work - Viking 3048SS brand new range hood

There is the on off switch and the blower control that controls the speed of the fan. It is more than likley the blower control that would need replaced.

There could also be a wire disconnected in the hood.
Not finding what you are looking for?

806 views

Ask a Question

Usually answered in minutes!

Top Viking Kitchen Ranges Experts

Paul Carew

Level 3 Expert

3808 Answers

ZJ Limited
ZJ Limited

Level 3 Expert

17989 Answers

Cindy Wells

Level 3 Expert

6688 Answers

Are you a Viking Kitchen Range Expert? Answer questions, earn points and help others

Answer questions

Manuals & User Guides