1 red blink every 2.5 seconds indicates a cover error-- for this check the lamp cover
2 times red blinks very 2 seconds indicates temperature error. for this let the projector cool off check filters and fans that there is no blockage of air for proper cool down
3 red blinks every every 2 seconds Power error. incorrect voltage input or internal malfunction.
4 red blinks every 2 seconds indicates Fan Error check the fans make sure they are working and not blocked or need replacing.
i have nothing on 6 ligths go ahead reconect and check for proper count. hope this information helps.
Best of Luck.
Ray.
E225
0000 A specific level cannot be attained for the signal during CCD gain correction
at power-on.
0002 The edge gain correction level is different from the correction level for the
preceding sheet by a specific level or more.
Main cause The scanning lamp is faulty. The CCD PCB is faulty. The rear controller
PCB is faulty.
Action
1. Scanning lamp (LAMP1)
Is the lamp ON during the initial operation after the main power switch is
turned on?
NO: Replace the scanning lamp.
2. CCD unit, Reader controller PCB
Try replacing the CCD unit. Is the problem corrected?
YES: End.
NO: Replace the reader controller PCB.
974 views