Error 30 shows when i press quick start?? - Precor C954i Commercial Treadmill

Posted by on

Ad

2 Answers

  • Level 3:

    An expert who has achieved level 3 by getting 1000 points

    All-Star:

    An expert that got 10 achievements.

    MVP:

    An expert that got 5 achievements.

    President:

    An expert whose answer got voted for 500 times.

  • Precor Master
  • 832 Answers

Any 30 series error code means that their is no communication between upper and lower boards. The main Telco harness ( looks like a telephone or DSL wire) my have a bad or broken connection. Unplug unit and taken motor shroud off and check connections should be able to plug and unplug same goes with upper console. If this does not help then either call a local service provider or call Precor directly give them the Model# and Serial# for this unit. They should provide you with the additional info needed
Good Luck!!
MAX

Posted on May 09, 2011

Ad
  • Level 3:

    An expert who has achieved level 3 by getting 1000 points

    Superstar:

    An expert that got 20 achievements.

    All-Star:

    An expert that got 10 achievements.

    MVP:

    An expert that got 5 achievements.

  • Precor Master
  • 918 Answers

Precor Error 30, 31, 32 and 33, Communications Error Probable Cause 1. Bad interconnect cable between upper PCA and lower PCA.
2. Interconnect cable is mistakenly plugged into the CSAFE connector at the upper PCA.
3. Elliptical 5.17 equipped with old software version 1.01 in upper and lower PCA.
4. Upper and lower PCAs have mismatched software.
5. Another component plugged onto the PCA is overloading the +5VDC power supply.
6. Bad lower PCA.
7. Bad upper PCA.
Corrective Action

  1. Test unit with a know good interconnect cable or test the interconnect cable for continuity. Replace interconnect cable if necessary.
  2. Disconnect the interconnect cable from the CSAFE connector and attach to the proper position on the upper PCA.3.
  3. Replace the upper and lower software of the 5.17 elliptical with the most current versions.4.
  4. If one of the PCAs is found to have software version 1.01, replace it with the most current software version.
  5. Disconnect all components from the upper and lower PCA leaving the data cable connecting between the upper and lower PCAs and the AC power going to the lower PCA. If the unit shows any error other than the error 3x, reconnect components one at a time. Reset power between each newly connected component until the error 3x reappears. Whichever component was last connected when the error 3x reappears, is the cause for the error. Replace the faulty component.
  6. Test unit with a known good lower PCA. Replace the lower PCA if necessary.
  7. Test unit with a known good upper PCA. Replace the upper PCA if necessary.
Precor Error Code 30 31 32 33

Posted on May 12, 2014

Ad

1 Suggested Answer

6ya6ya
  • 2 Answers

SOURCE:

Hi there,
Save hours of searching online or wasting money on unnecessary repairs by talking to a 6YA Expert who can help you resolve this issue over the phone in a minute or two.

Best thing about this new service is that you are never placed on hold and get to talk to real repairmen in the US.

Here's a link to this great service

Good luck!

Posted on Jan 02, 2017

Add Your Answer

Uploading: 0%

my-video-file.mp4

Complete. Click "Add" to insert your video. Add

×

Loading...
Loading...

Related Questions:

1 Answer

How do you fix an error code 30 on a precor 954i?


Precor Error 30, 31, 32 and 33, Communications Error Probable Cause 1. Bad interconnect cable between upper PCA and lower PCA.
2. Interconnect cable is mistakenly plugged into the CSAFE connector at the upper PCA.
3. Elliptical 5.17 equipped with old software version 1.01 in upper and lower PCA.
4. Upper and lower PCAs have mismatched software.
5. Another component plugged onto the PCA is overloading the +5VDC power supply.
6. Bad lower PCA.
7. Bad upper PCA.
Corrective Action
  1. Test unit with a know good interconnect cable or test the interconnect cable for continuity. Replace interconnect cable if necessary.
  2. Disconnect the interconnect cable from the CSAFE connector and attach to the proper position on the upper PCA.3.
  3. Replace the upper and lower software of the 5.17 elliptical with the most current versions.4.
  4. If one of the PCAs is found to have software version 1.01, replace it with the most current software version.
  5. Disconnect all components from the upper and lower PCA leaving the data cable connecting between the upper and lower PCAs and the AC power going to the lower PCA. If the unit shows any error other than the error 3x, reconnect components one at a time. Reset power between each newly connected component until the error 3x reappears. Whichever component was last connected when the error 3x reappears, is the cause for the error. Replace the faulty component.
  6. Test unit with a known good lower PCA. Replace the lower PCA if necessary.
  7. Test unit with a known good upper PCA. Replace the upper PCA if necessary.
Precor Error Code 30 31 32 33

Jun 30, 2014 | Precor Exercise & Fitness

1 Answer

Ge front load error codes t01


make this test: God bless you

- 45 -
Service Test Mode
The dryer control has a service test mode that can be utilized by the service technician in order to test
critical components and to access error codes. This test mode will help the service technician to quickly
identify failed or improperly operating dryer components.

Test Mode Description
t01 Model ID Verifi
es (or sets on new board) the proper model id.
t02 Error Codes Lists up to 10 control-detected problems.
t03 Software ID
Displays the software version number and the non-
volatile memory version number.
t04 Program Non-volatile Memory Test Control computes and compares the 16-bit CRC of
the non-volatile memory with the pre-computed
version stored in the non-volatile memory.
t05 User Interface Control turns on all LEDs and the 7-segment display.
t06 Keys Continuity Verifi
es that all displays and buttons work.
t07 Outlet Thermistor Displays outlet thermistor temperature.
t08 Inlet Thermistor Displays inlet thermistor temperature.
t09 Moisture Sensor Displays voltage read from the moisture sensor.
t10 Exhaust Detection Verifi
es status of the exhaust system.
To enter the test mode: To exit the test mode:
Disconnect the power for 30 seconds.
Reconnect power and within 30 seconds of
reconnecting power:
Press signal button.
Press delay start button.
Press signal button.
Press delay start button. (Displays t01)
1.
2.
a.
b.
c.
d.
Press the power button during the test selection
mode.
Note:
A dryer left in the test mode will exit the test
mode after a period of 30 minutes

Oct 01, 2013 | GE Dryers

1 Answer

Oven: false lock error


Check your thermal regulator located on the back, it is most likel a 2 screw part replacement. Thats What it was on ours, very quick and easy fix.

Jan 14, 2018 | Maytag PER5710 Performa Electric Kitchen...

1 Answer

I am trying to start a cyle and everytime i push the cycle button it does not light up and the quick rinse button comes on and flashes nothing works at all if i push heavy wash it comes on and nothing...


You haven't told me how many times the light flashes, but I will take a guess that this is an error code associated with the water entering the machine being too cool. I believe the machine expects the water to enter at 110 degrees F (43 Degrees C).

To clear the error, press "Heated Dry" then release, then press "Normal Wash" then release and repeat this sequence until all the lights on the machine go solid green. Once this happens, hit ""Cancel" and the machine will reset.

The fix for the root of the problem is to increase the temperature of the incoming water in future (Turn up your water heater temperature a little)

Jul 05, 2011 | Kenmore Elite Stainless Steel 24" BuiltIn...

2 Answers

Sir how to reinstall quickheal trial version we always use trial version for 30 days before 30 days we are delete old version and use the new one trial version for next 30 days but now i have install 11.00...


Hiii


May be you u cross the trial version limit ( Some company provide the 3 time use the trial version) now purchase the license, other option u have to format your computer but its not recommended.

Good Luck

May 11, 2011 | Computers & Internet

2 Answers

Stirling XQG65-908E E11 error clothes stuck in machine. Machine is lock and clothes are inside


Buttons:
Pre-Wash = K1
Delay = K2
Temp = K3
Spin Speed = K4
Add Garment = K5
Extra Rinse = K6 1. Press K3, K5, K3, K5 in 30 seconds after power on to enter serve mode(txx selection mode). The display will show t01.
2. Press K1 or K2, it will change from t01 to t12.
3. Press "start/pause" key to enter txx measure mode. Run txx after"start/pause" key. You can go back to txx selection mode if press "start/pause"key.
b. t02:Show fault code test
Press K1, K2 can see all record fault code EXX after enter t02. You can cleanupthe fault code per hold K2 for 3 seconds. If error code 11 does not go away after doing the above 3 times, then theremay be something wrong with the inlet valve, drain pump or PCB.

Jan 16, 2011 | Washing Machines

2 Answers

What does it mean error 5b00, and how do i resolve it


You will have to do a reset. Follow the instructions below
1. power off.
2. hold stop/reset, hold ON/OFF
3. release stop/reset, push stop/reset twice, quickly, then release ON/OFF
4. wait untill LCD display shows “Canon Idle”,then push stop/reset four times, quickly
5. then push power twice, quickly
6. power off and power on

Jul 14, 2010 | Canon PIXMA MP130 All-In-One InkJet...

1 Answer

Error Message with D70 when pressing Shutter


No quick fix on this one... mine is fully jammed now, was sporaic previously.

Best option is to get it serviced or upgrade like I did...

Apr 27, 2008 | Nikon D70s Digital Camera

Not finding what you are looking for?
Precor C954i Commercial Treadmill Logo

5,713 people viewed this question

Ask a Question

Usually answered in minutes!

Top Precor Exercise & Fitness Experts

Jose Pino

Level 3 Expert

563 Answers

Ross Metcalfe
Ross Metcalfe

Level 2 Expert

135 Answers

Tom Chichester

Level 3 Expert

51893 Answers

Are you a Precor Exercise and Fitnes Expert? Answer questions, earn points and help others

Answer questions

Manuals & User Guides

Loading...