Any 30 series error code means that their is no communication between upper and lower boards.
The main Telco harness ( looks like a telephone or DSL wire) my have a bad or broken connection. Unplug unit and taken motor shroud off and check connections should be able to plug and unplug same goes with upper console. If this does not help then either call a local service provider or call Precor directly give them the Model# and Serial# for this unit. They should provide you with the additional info needed
Good Luck!!
MAX
Precor Error 30, 31, 32 and 33, Communications Error
Probable Cause
1. Bad interconnect cable between upper PCA and lower PCA.
2. Interconnect cable is mistakenly plugged into the CSAFE connector at the upper PCA.
3. Elliptical 5.17 equipped with old software version 1.01 in upper and lower PCA.
4. Upper and lower PCAs have mismatched software.
5. Another component plugged onto the PCA is overloading the +5VDC power supply.
6. Bad lower PCA.
7. Bad upper PCA.
Corrective Action
Precor Error Code 30 31 32 33
10,831 views