Hey
just wondering if anyone had this problem as well.
the tablet(finish) isn't dissolving -seems to be only rinsing - even though its on a normal cycle.
could it be related to the pump - how do i fix that?
or could it be related to a blockage in the drain?
thanks for your help:)
It's the electronic switch that releases the door in the cycle mode, mostly it's the connection that's a bit corroded it causes the door to stick and when it does release the cycle usually has finished leaving the pod in the compartment.
I was going to replace the whole unit but removed the front panel, screws from inside the door when open and could see the unit so gave it a clean and used some silicone grease on connection plug and pins, then put it back together and it cured this issue.
Open the door when in cycle and check both spray arms are rotating. you will get a bit of water out but not a lot. if arms not rotating, then this is caused usually by rubbish in the spray arm jets so clean them. also check water is being heated
926 views