The motor will run hot/overload if wrong size or too long cord is used. Also if pressure is set too high (most set at 125 ~ 135 at shut-off). In-tank checkvalve will also have effect on motor by loading the compressor at start-up. Easy test. Run compessor till you have over 100lbs in tank then unplug from power. At this point try to turn the motor /pump by hand, it should turn rather/very easily (this test is hard to do if the motor /pump is completely enclosed, you need to be able to turn the pump even if by truning the fan blade). If it does not turn easily let all the air pressure out of tank and then try to turn by hand. If it turns easily with tank empty try one more test. Run compessor till the pressure switch turns it off. Then unplug machine and turn compessor again by hand, should be easy. If not easy then unloader / checkvalve not working. The checkvalve could be leaking air back from the tank loading the pump. Replace parts as needed.