RTO Takagi T-M1 Mobius Gas Tankless Water Heater Logo
Posted on Mar 18, 2011

My Takagi T-M1 water heater is not functioning. After less than a minute of operating it stops and the red light in the front is blinking.

1 Answer

Anonymous

Level 1:

An expert who has achieved level 1.

New Friend:

An expert that has 1 follower.

  • Contributor 1 Answer
  • Posted on Apr 07, 2011
Anonymous
Contributor
Level 1:

An expert who has achieved level 1.

New Friend:

An expert that has 1 follower.

Joined: Apr 07, 2011
Answers
1
Questions
0
Helped
1605
Points
1

I HAD THE SAME PROBLEM. I CONTACTED TAKAGI WHO SENT OUT THE REPLACEMENT PART. AFTER INSTALLING THAT PART, IT WORKED FOR A MINUTE AND STOPPED. I CONTACTED TAKAGI ONCE AGAIN AND WAS TOLD "OH, THAT MOTHERBOARD GOES OUT SOMETIMES IF THAT FIRST PART GOES BAD!" THEY THEN SENT OUT A NEW MOTHERBOARD WHICH FIXED THE PROBLEM.

Add Your Answer

×

Uploading: 0%

my-video-file.mp4

Complete. Click "Add" to insert your video. Add

×

Loading...
Loading...

Related Questions:

0helpful
1answer
1helpful
1answer

Code 211 comes on but vent is clear of any debris or blockage. Sometimes can go days without alarm sounding sometimes alarm sounds 3-4 times in 10 minutes.

Generally tankless must be maintained on yearly basis.
Error codes are usually stored in the computer memory until they reach a threshold and then the error code is displayed... it is possible the control board is bad.. or the sensor that feeds information to the control board is bad.
Contact manufacturer or installer.
Contact local service technician who is qualified on that specific brand.

Gene
http://waterheatertimer.org/Whirlpool-Energy-Smart-electric.html

Water Heater Timers Save Money

If you need further help, I’m available over the phone at https://www.6ya.com/expert/gene_9f0ef4df2f9897e7

0helpful
1answer

No hot water

This indicates a reduced supply of water to the heater. Check water flow through the tap has not been reduced If so, check filter area
0helpful
1answer

Error code 111

checked for long time final find out the sensors socket has some water in it and I dry it out and the heater fire up right away "hope this can help other people " good luck.
1helpful
1answer

Error code 541

Error Code 541 indicates that the Two Way Valve is malfunctioning. This assembly consists of a small motor and a rotating ball valve that is operated by the motor. The replacement part is only sold as a unit (Motor and valve) for about $200. It is located in the lower left of the unit, behind the flow valve. (i.e. it is hard to reach in order to service it). You basically have to take out the exhaust fan, take out the flow valve in order to replace the 2-way valve. It's doable as a DIY, but it's not trivial.

The valve could be crusty from deposits, so before taking everything apart, it would be wise to flush the heater for 45 minutes with anti-scaling and a recirculating pump to see if anything breaks loose. (using the service valves that should be mounted on the bottom of the unit)
1helpful
2answers

Takagi code 541

Code 541 means the 2 way valve is not turning, that could be the valve has build up calcium due to hard water and the attached motor is not able to turn it, or the motor is broke or finally the controller (Compute Board is defective).
The 2 wau valve sits behind another valve when looking at the unit on the left hand corner, it must be taken out first to gain access to the 2 way valve.
The 2 way valve motor can be seperated from the valve by two screws and the valve can be manually opened but turning it to the horizantal position, there is a pin on that shaft.
Turn kon the heater then but leave the motor connected, if the motor turns for short time then the PCB is most likely ok. This usually indicated that there is too much of build up inside the valve. If the tankless was properly with bypass valves (outside of the unit) installed then this can be easily fixed.
Turn the unit off and run with an external pump and bucket with vinegar for about 30 minutes by using the bypass valves. This will clean the 2 way valve from inside and should turn then easily and the motor will be able to control it. This is usually beyond the DIY scope, call a real pro for that.
http://www.justtankless.com
3helpful
1answer

Code 991 continues to show.. will not clear... how do we clear that code???

to clear the 991 Takagi code, simultaneously press the bottom 2 grey buttons of the four just to the left of the flashing LED light. When the LED stops flashing, release and then press the reset button on the black panel about 8 inches above that
1helpful
1answer

Takagi Jr Flash Water Heater Problem

explain your problem.
Takagi is a great tankless heater, very few problems...

need more info
0helpful
1answer

Pilot fires then quickly shuts off how do I pull a code on a Takagi T-K2?

Pilot must heat the thermocoupler a couple of minutes before letting go of the button. The coupler controls the main valve.
Not finding what you are looking for?

1,615 views

Ask a Question

Usually answered in minutes!

Top RTO Water Heaters Experts

Brad Brown

Level 3 Expert

19187 Answers

Sean Wright
Sean Wright

Level 3 Expert

2045 Answers

Paul Carew

Level 3 Expert

3808 Answers

Are you a RTO Water Heater Expert? Answer questions, earn points and help others

Answer questions

Manuals & User Guides

Loading...