Powerware 9120 6000i 6kVA ups indicates a charger failure. Can you give us a solution, this is the first time that the unit failed and we're not sure of the charger circuit location (we do not have a digram). thanks
- If you need clarification, ask it in the comment box above.
- Better answers use proper spelling and grammar.
- Provide details, support with references or personal experience.
Tell us some more! Your answer needs to include more details to help people.You can't post answers that contain an email address.Please enter a valid email address.The email address entered is already associated to an account.Login to postPlease use English characters only.
Tip: The max point reward for answering a question is 15.
Did your UPS display "Battery disconnected" or did it display "Battery Failure"? If it was "Battery Failure", for some reason the Powerware 9120 will take almost 18 hours after plugging in to power after battery replacement to correct the Battery Failure indication. Charger has to charge up the batteries, followed by an automatic battery test by the UPS. If the indication was "Battery Disconnected", you will need to check the internal fuses to see if they are blown. If the UPS keeps blowing fuses, it will require a board repair.
The charger in powerware 9 series 9120 6000i ,the fan is of a quality that it fails and the heat sink does not get sufficient cooling ,it runs on 12 volt ,i replaced it with a cpu fan from a mainboard on a pc and it works perfectly now. make sure that the fan is running else the charger might go in protection or can fail due to the transistor on heat sink fails.