F5 - E1
Self clean latch will not lock
1. If door
latched:
- Disconnect power from unit.
- Check wires and connectors from control to door switch, then from
door switch to control. If no damage to wires and all connectors okay,
proceed to step C.
- Replace door switch.
- Re-apply power.
- Press and hold any key down for 1 minute to clear F5 failure code
from memory. F2 will appear. Press CANCEL and observe for 1 minute to
ensure operation is correct.
2. If door
not latched:
- Disconnect power from unit.
- Check wires and connectors from control to latch switch, then from
latch switch to control. If no damage to wires and all connectors okay,
proceed to step C.
- Repeat steps A and B for door switch.
3. Measure door switch (door open = switch open small low voltage
terminals). Replace switch if defective.
4. Measure latch switch (unlatch = switch open, CAUTION - oven light
contacts are closed). Replace switch if defective.
5. If corrections are made in any step, reconnect power to control.
Press and hold any key for 1 minute to clear R failure code from memory.
F2 will appear. Press CANCEL and observe for 1 minute to ensure
operation is correct.
6. If failure remains, disconnect power and replace control.
×