Hi,
I have a Heller Gusty10c0 Portable Air Con. When It hasn't been used for a while. I turn it on and it last about 10 minutes then just stops. Then when ever I turn it on it cuts out after about 30 secs to a minute. Can anybody help me please?
I have a Heller Gusty10c0 Portable Air Con. When It hasn't been used for a while. I turn it on and it last about 10 minutes then just stops. Then when ever I turn it on it cuts out after about 30 secs to a minute. Can anybody help me please?
I have the same model and it did the same thing. It has something to do with the water collecting in the bottom tray. I completely drained it and left it run on fan to try and clear up the water but to no avail. I found after taking the front panel off there is a black control panel with two screws holding the cover on. Take them off and there is a connection with two white cables coming out that says something like water level (this is shown on the cover). It also says WT next to the cable ( I assume as they are white). Take that out. My ac has been running all day now with no stopping. The white able runs to two screws in the bottom water tray and I assume that it to measure how much water is in there. Only is sure with this fix that you will have to watch the water as it will no longer tell you when it is full. I put a towel under it just in case but hey, it hasn't stopped.
×