After turned down the thermostat the refrigerator nerver start. we have lite, it is dispensing tce but it is defrosting for 2 days

1 Answer

Anonymous

Level 3:

An expert who has achieved level 3 by getting 1000 points

All-Star:

An expert that got 10 achievements.

MVP:

An expert that got 5 achievements.

Vice President:

An expert whose answer got voted for 100 times.

  • Master 348 Answers
  • Posted on Nov 26, 2010
Anonymous
Master
Level 3:

An expert who has achieved level 3 by getting 1000 points

All-Star:

An expert that got 10 achievements.

MVP:

An expert that got 5 achievements.

Vice President:

An expert whose answer got voted for 100 times.

Joined: Oct 15, 2009
Answers
348
Questions
7
Helped
99486
Points
1063

This is only a guess. Try unplugging it for 1 hour then plug it back in. This may reset your thermostat. Good luck Google burdfrenzy

Add Your Answer

×

Uploading: 0%

my-video-file.mp4

Complete. Click "Add" to insert your video. Add

×

Loading...
Loading...

Related Questions:

0helpful
1answer

How do i get unit to go in deforst

The refrigerator/freezer defrost system can be checked by manually initiating a defrost cycle. There
are two methods of initiating the ADC Test Mode.
First Test Method:
1. Turn the thermostat off for 15 seconds.
2. Turn the thermostat on for 5 seconds.
3. Turn the thermostat off for 15 seconds.
4. Turn the thermostat on for 5 seconds.
5. Turn the thermostat off for 15 seconds.
6. Turn the thermostat on for 5 seconds.
7. Turn the thermostat off.
In 3 to 8 seconds the ADC should turn on the defrost heater (with the bimetal closed). NOTE: The test mode will terminate when the bimetal opens. If the refrigerator/freezer is already in defrost, Test Mode can be terminated by unplugging the refrigerator/freezer from the wall outlet and waiting 30 seconds before plugging it back in. The refrigerator/freezer should immediately go into cooling mode if the thermostat is closed.
If this first test procedure fails to make the ADC initiate a defrost cycle, try the following procedure to make the ADC begin the Test Mode.
Second Test Method:
1. Disconnect the refrigerator/freezer from the wall outlet for at least 30 seconds.
2. Turn the thermostat off.
3. Reconnect power to the refrigerator/freezer.
Within 3 to 8 seconds the ADC should turn on the defrost heater (with the bimetal close). If the unit fails to go into the defrost mode during this test, the problem may not be with the ADC. A defective bimetal may be the cause of the failure. The ADC will only go into a test mode if the bimetal
is closed. If the ADC senses an open bimetal it will return to the cooling mode within 3 to 8 seconds.
HELPFUL HINT: Upon entering the Test Mode, the relay mounted on the ADC board should turn off the compressor and turn on the defrost heater. Listen for the relay to click.
• If the relay clicks one time when entering the Test Mode, check for continuity in the defrost heater.
• If the relay clicks two times, check for an open bimetal.

0helpful
1answer

It is not cooling as it should like a refrigerator. As if the fan is on.

How to check everything
http://www.acmehowto.com/howto/appliance/refrigerator/refrigerator.php
If the evaporator coils behind the back panel of the freezer are icing up because of auto defrost failure that will stop the circulation of cold air and eventually affect the freezer too.

check defrost timer, defrost heater, defrost thermostat. In most newer models the timer has been replaced by an electronic control board. If the heater and thermostat are ok it’ll be the control.

You can turn the defrost timer till it clicks and everything shuts down. The heater should now come on. If it does, replace the timer. If it doesn't, check the heater and defrost thermostat. Turn the timer again till everything starts back up to end the defrost cycle.


0helpful
1answer

My whirl Pool side by side is not cooling well, I have washed the coils completely and used the recommended thermostat settings, but I have had thawing in the freezer and in the refrigerator,the freezer...

How to check everything
http://www.acmehowto.com/howto/appliance/refrigerator/refrigerator.php


The fridge gets its cold air from the freezer through a vent(damper) between the freezer and fridge.The fan in the freezer blows air through it. There is a flap you adjust with the fridge temp. control. Make sure it's opening and closing when you adjust the fridge temp

..
If the evaporator coils behind the back panel of the freezer are icing up because of auto defrost failure that will stop the circulation of cold air and eventually affect the freezer too.

check defrost timer, defrost heater, defrost thermostat. In most newer models the timer has been replaced by an electronic control board. If the heater and thermostat are ok it’ll be the control.

You can turn the defrost timer till it clicks and everything shuts down. The heater should now come on. If it does, replace the timer. If it doesn't, check the heater and defrost thermostat. Turn the timer again till everything starts back up to end the defrost cycle.


0helpful
1answer

Well My Superba Model number KSRB25FHSS02 is not defrosting!

How to check everything
http://www.acmehowto.com/howto/appliance/refrigerator/refrigerator.php


If the evaporator coils behind the back panel of the freezer are icing up because of auto defrost failure that will stop the circulation of cold air and eventually affect the freezer too.

check defrost timer, defrost heater, defrost thermostat. In most newer models the timer has been replaced by an electronic control board. If the heater and thermostat are ok it’ll be the control.

You can turn the defrost timer till it clicks and everything shuts down. The heater should now come on. If it does, replace the timer. If it doesn't, check the heater and defrost thermostat. Turn the timer again till everything starts back up to end the defrost cycle.
1helpful
1answer

Frig too warm, freezer works great, but frost on back wall

It sounds like the fridge is not going through the defrost cylce due to a faulty defrost thermostat.
1helpful
1answer

GE Fridge not cooling well, frost in freezer,back wall and coils

How to check everything
http://www.acmehowto.com/howto/appliance/refrigerator/refrigerator.php
check defrost timer, defrost heater, defrost thermostat. In most newer models the timer has been replaced by an electronic control board. If the heater and thermostat are ok it’ll be the control.

You can turn the defrost timer till it clicks and everything shuts down. The heater should now come on. If it does, replace the timer. If it doesn't, check the heater and defrost thermostat. Turn the timer again till everything starts back up to end the defrost cycle.
0helpful
1answer

Ice building up in fridge


If the evaporator coils behind the back panel of the freezer are icing up because of auto defrost failure that will stop the circulation of cold air and eventually affect the freezer too.
How to check stuff>
http://www.acmehowto.com/howto/appliance/refrigerator/refrigerator.php check defrost timer, defrost heater, defrost thermostat. In most newer models the timer has been replaced by an electronic control board. If the heater and thermostat are ok it’ll be the control.

You can turn the defrost timer till it clicks and everything shuts down. The heater should now come on. If it does, replace the timer. If it doesn't, check the heater and defrost thermostat. Turn the timer again till everything starts back up to end the defrost cycle.


Your evaporator coils frost up in normal use and every eight hours or so the entire unit shuts down and the defrost heater comes on to melt the frost. This cycle last about 20 minutes. The melted frost drips into a drain pan and through a drain tube to the drain tray under the freezer/refrigerator where it's evaporated by the condenser fan.
1helpful
1answer

Light on in fridge but no compressor sound or clicks or fan

That dude is probably stuck in the defrost mode.
OK try this:
1. Unplug refrigerator
2. Turn Cold Control to “off (Compressor is off)
3. Plug in refrigerator
The defrost cycle has now been initiated. The DTT has a bypass/test point for diagnosis. To terminate defrost manually:
1. Unplug the refrigerator
2. Turn the cold control “on” (Compressor is on)
3. Plug in the refrigerator
The defrost cycle is terminated and refrigeration cycle resumes.
Replace the dang adaptive defrost if you cannot get any response.


If you need further help, reach me via phone at https://www.6ya.com/expert/dan_73bbd84fe1d95b61

1helpful
1answer

Refridgerator acting erratic

The refrigerator/freezer defrost system can be checked by manually initiating a defrost cycle. There
are two methods of initiating the ADC Test Mode.
First Test Method:
1. Turn the thermostat off for 15 seconds.
2. Turn the thermostat on for 5 seconds.
3. Turn the thermostat off for 15 seconds.
4. Turn the thermostat on for 5 seconds.
5. Turn the thermostat off for 15 seconds.
6. Turn the thermostat on for 5 seconds.
7. Turn the thermostat off.
In 3 to 8 seconds the ADC should turn on the defrost heater (with the bimetal closed). NOTE: The test mode will terminate when the bimetal opens. If the refrigerator/freezer is already in defrost, Test Mode can be terminated by unplugging the refrigerator/freezer from the wall outlet and waiting 30 seconds before plugging it back in. The refrigerator/freezer should immediately go into cooling mode if the thermostat is closed.
If this first test procedure fails to make the ADC initiate a defrost cycle, try the following procedure to make the ADC begin the Test Mode.
1helpful
1answer

I have a GE SxS that I bought in Sept. 06. About

First you need to turn the freezer temp control back on(That just turned the whole refrigerator off)
The water dispenser may have stopped due to line freezing inside the refrigerator.
The ticking could have been the the element for the defrost cycle or the starter on the compressor.
So,turn it back on,set the temp to a normal setting and if the ticking is still there,wait 30 minutes to see if it stops,If no ticking is there when you restart it,wait 24 hour and check the temp inside as well as the water and ice dispenser,If all work,It is a defrost issue.If so you will either need a defrost timer,defrost element,or defrost thermostat.
If the ticking is still there,You will need to replace the start/run capacitor.
Not finding what you are looking for?

46 views

Ask a Question

Usually answered in minutes!

Top Kenmore Refrigerators Experts

vince

Level 3 Expert

2530 Answers

Cindy Wells

Level 3 Expert

6688 Answers

Johnny 1000

Level 2 Expert

94 Answers

Are you a Kenmore Refrigerator Expert? Answer questions, earn points and help others

Answer questions

Manuals & User Guides

Loading...