Make sure u remove the fill plug and not the drain! In any case it seems like u may have overfilled it. Make sure you read the instruction in proper oil level.
The reduced atmospheric pressure at high altitude means the standard carburettor settings will not allow sufficient fuel to flow for efficient running.
The dealer or manufacturer should be able to provide details of alternative settings - the jet sizes are usually increased a few points for every 5000 ft above sea level.
The cooler temperatures experienced at high altitude would probably change the engine oil specification to a lighter or thinner grade.
Check oil level, may have low oil sensor which will shut it down each time within seconds.
if oil is low add some see if that takes care of it,if not test the sensor
Those generators are set up with a low oil saftey but your gonna want to check compression anyways just to verify it is where it needs to be. Im gonna guess its to be between 120-160 psi, check your manual for the service limits. after that check your air filter, valve lash, fuel filter etc etc.
The Choke's function is to limit air intake till engine reaches opperating temperature.It should decrease to nill if auto.If not then try increasing the idle.Good Luck.
you should have a drain plug at the side and bottom of the motor crank case its a small plug with a square head how old is your generator if new put 10w30 oil if old put sae30w if really bad add some lucas oil treatment also now a 9 h.p. should take less then 2 quarts
×