Model sl-1650 direct drive automatic table. arm will not place itself at beginning , first track, of lp. arm consistently travels to center, . position never varies. works fine manually - place arm/needle/cartridge on first track and it plays to end and comes to a stop when no additional lp has been placed on spindle. if so new record will fall properly and arm will travel to center. anyone know what's the problem and how to fix?

5 Related Answers

Anonymous

  • 2 Answers
  • Posted on Nov 21, 2007

SOURCE: Needle drag

Hi, i know this sounds stupid but have u tried using a different record as the record your using may have a defect which wont allow it to play any further. I would also make sure that you weight the tonearm as much as possible but not to much that you wear ur needles out. Let me know how you get on. Gud luck!

Ad

Anonymous

  • 178 Answers
  • Posted on Feb 13, 2008

SOURCE: tone arm is hard to move

You have a bad tone arm. I have the same tables. You need to get it repaired if under warrenty. Or there is a service manaul online you can get from ebay. Service center for our tables is Panasonic.

I had the same problem on mine. But while it is in the shop they recalibarte it

Anonymous

  • 515 Answers
  • Posted on Jul 02, 2008

SOURCE: Technics SL 1600 MK2

Your tonearm is damaged. More than likely the bearings on the tonearm have been damaged. Unfortunately, there is no easy fix for this. You'll have to have the tonearm replaced, however, parts for the SL1600MK2 have been discontinued. The tonearm for the SL1200MK2 might fit it, but you will need to do some retro-fitting in order to make it work properly. Something only a qualified service center could perform.

Hope this helps some.

Good luck!


DIGITAL ANALOG THERAPY

Anonymous

  • 515 Answers
  • Posted on Jul 12, 2008

SOURCE: technics sl-ql 15 linear tracking T/Table

Parts are discontinued for these models. You need what's called a P-Mount cartridge screw. Try the following company:

www.lpgear.com

Good luck!

- DAVIS
DIGITAL ANALOG THERAPY
www.repairnyc.com
www.1200s.com

Anonymous

  • 113 Answers
  • Posted on Jul 22, 2009

SOURCE: Sears Tape deck/Turn table skipping!

Hi the pennies will mess up the stylus. There should be an anti skate setting at the back of the turn table, a round adjustable bit with numbers, increase the anti skate and then use the balance weigth (weight right at the back of the arm that turns to get the weight right. Set the anti skate with the tone arm light, then increase the weight a bit. Hope that helps

Ad

Add Your Answer

×

Uploading: 0%

my-video-file.mp4

Complete. Click "Add" to insert your video. Add

×

Loading...
Loading...

Related Questions:

1helpful
2answers

Optimus lab 1100. Huge distortion. I place my finger on the arm and all is good. Any idea ?

it is not a computer or PC so moved YAH/
it is home stereo sound turntable .from RADIO SHACK.
that that is easy seen it vast times back in the 60s.
  1. the pickup cartridge the needle there is packed in lint clean it .
  2. if not that , the tracking pressure is set wrong, RTM.
  3. if not that the tracking arm is binding find where and correct that.
  4. the needle is bad. (or its cartridge.
the manuals says, not adjustable, making this turntable junk class.
Ive owned many and this is junk.
that failures is pure mechanics, only.
here is mine, a real TT (note the brand)

https://imboldn.com/technics-sl-1200g-direct-drive-turntable/

note tracking controls full .
after a new cartridge upgrade that ways less it must be re calibrated for pressure and tracking. or fails.
0helpful
1answer

Owners manual for SL-L3 turntable

Two Speed Direct Drive Fully Automatic Turntable with linear tracking ... Technics SL-L3 / SLL3 owners manual, service manuals and schematics are for ... www.vinylengine.com/library/technics/sl-l3.shtml

hope this will be of help
0helpful
1answer

Tone arm pulls in one direction

If the force is towards the center of the disk, it's OK, it's the antiskating force. Set antiskating at 0, set the weight at 0gr, turn around the makeweight in order to set the tone arm parallel to the disk. With the antiskating at 0 the tone arm will stay parallel to the disk in the place you leave it. With the antiskating at any other position the tone arm will stay parallel to the disk going towards the center of the disk.

In case of a problem or clarification, don't hesitate to post.

Thanks and regards
Please kindly rate this solution
Stelios
direct FiXya link: http://www.fixya.com/users/technical114
0helpful
2answers

Hi. I'm have a problem with my Technics SL-BD20 turn table I've just purchased. When putting the arm onto the LP it just skips over the surface to the middle. Why does it do that? Cheers.

Try adjusting the tone arm weight so that the arm will be slightly heavier.

If this does not help, see if the tone arm manual lift handle is operational and fully released when the arm sits on the record.

Another possible cause are the tone arm position sensors inside the unit.

Hope you can fix it.

regards

Triarcuate
0helpful
1answer

Technics sl-ql 15 linear tracking T/Table

Parts are discontinued for these models. You need what's called a P-Mount cartridge screw. Try the following company:

www.lpgear.com

Good luck!

- DAVIS
DIGITAL ANALOG THERAPY
www.repairnyc.com
www.1200s.com

0helpful
1answer

Technics SL 1600 MK2

Your tonearm is damaged. More than likely the bearings on the tonearm have been damaged. Unfortunately, there is no easy fix for this. You'll have to have the tonearm replaced, however, parts for the SL1600MK2 have been discontinued. The tonearm for the SL1200MK2 might fit it, but you will need to do some retro-fitting in order to make it work properly. Something only a qualified service center could perform.

Hope this helps some.

Good luck!


DIGITAL ANALOG THERAPY

0helpful
1answer

Crosley CR-49 Turn table stops and will not play when needle arm is positioned to play a song toward the end of the 33 album.

The tone arm may have been forced out of spec to play an entire LP, or the auto cutout function of the player appears to be operating.
If out of adjustment(someone has forced it), the problem can be resolved by loosening the screw that locks the tonearm to its turret, and adjusting the end travel against the distance to the end of the LP you mentioned it wont play. Then of course tighten the locking screw again

Another common problem, is where dried grease between the two small metal plates fixed to mechanism that engage against the center spindle to activate the autostop mechanism. You will need to remove the platter in most cases to get access to this autostop mech to clean away the dried grease and or adjust it.

Good Luck with your listening. Long Live Vinyl :)

regards
Graeme
0helpful
1answer

Tone arm is hard to move and when it's placed on a record the needle sticks at on spot on the record. the same needle and record plays fine on other technics 1200 mk5. seems like the arm has resistance in...

You have a bad tone arm. I have the same tables. You need to get it repaired if under warrenty. Or there is a service manaul online you can get from ebay. Service center for our tables is Panasonic.

I had the same problem on mine. But while it is in the shop they recalibarte it
0helpful
2answers

Sony PS-LX250H turntable won't turn

check the switch that make the lp running located it on the arm (arm uses to put it on the LP) check the motor Make sure no debris whatsoever that can disrupt the LP to turn
Not finding what you are looking for?

112 views

Ask a Question

Usually answered in minutes!

Top Technics Audio Players & Recorders Experts

 Grubhead
Grubhead

Level 3 Expert

5755 Answers

ZJ Limited
ZJ Limited

Level 3 Expert

17989 Answers

Kolbrun...

Level 3 Expert

1228 Answers

Are you a Technics Audio Player and Recorder Expert? Answer questions, earn points and help others

Answer questions

Manuals & User Guides

Loading...