SOURCE: I rented a Heater, Kerosene Reddy 165M PRO-165 for
The model of the unit is usually the BTU output, in this case 165,000 BTU
SOURCE: Reddy Heater 50'000 BTU - Puffs Smoke and Leaks Out The End
Hi,
Here are a couple of tips that I wrote that tell you how to troubleshoot aTorpedo or Reddy heater...
Reddy Heater - Troubleshooting Torpedo Heaters
Torpedo Heater Pump Pressure Adjustment
heatman101
/...
Hi,
Here are a couple of tips that I
wrote that tell you how to troubleshoot a Torpedo or Reddy
heater...
Reddy
Heater - Troubleshooting Torpedo Heaters
Torpedo
Heater Pump Pressure Adjustment
heatman101
=----------------------=
Absolutely K1 or diesel can get old in a hurry, the ultra-low Sulphur diesel has been tinkered with so much that it turns to book varnish much faster than before 2010. Most of those heaters spray fuel past the igniters using a siphon much like a spray paint gun, the suction tube may have dry rot or a small air leak and it it takes but a tiny air leak to kill the siphon effect. Check the tube from the nozzle all the way down to the fuel tank or replace it if you're not certain it is not compromised or dry rotted.