How do I calibrate my stanley laser level
to calibrate you need to have an area 75 to 100 feet in distance. place laser on tripod 20 feet from one end, take measurements on short and long end, then move laser to center of range and take measurements on both ends . the distance between both sets of marks should be within + or - 1/4 inch if not move level screw to move beam to center then center bubble
×