Plug the indicated end of the Transformer into the Rear Mech Cover . Plug the other end of the Transformer into a 120-volt outlet. All indicators and displays on the console will flash once; the console will then be ready for use. The motor may be heard while the resistance system calibrates itself. Important: Always plug in the transformer when using the resistance system.
Then, press and hold the NEXT button and the motorize resistance + button for five seconds. When the buttons are released, a number will appear in the REPS display. Press the NEXT button again, and then press the MOTORIZED RESISTANCE + button; this will start the recalibration process. This may take a few seconds as the motor moves between the lowest and highest resistance settings. When the motor finishes, unplug the transformer from the 120-volt outlet.
If you cannot hear the motor reset it self or cannot see display then with multi meter check DC voltage if not replace transformer , if you have DC voltage you will need to remove the cover locate the motor assembly disconnect the assembly from the upper electronics. Then apply a 12v DC voltage to the motor and see if it engages easily if not then replace motor. If motor functions properly replace connector back on the motor and use a multi meter connect it to motor and plug in the transformer and you should see DC voltage going to motor if not replace upper console.
967 views