These units have a history of fan failure due to inferior 220 volt Italian fan.
I have just had fan fail and retrofitted a ebmpapst blower fan model D2E146HT6702 which is readily available in Aus for around $120.
The fan speed control is by inverter variable output so you don't use all the speed select wires that this fan has. Connect the Red wire on the range hood to the Black on the motor (High speed winding) and the Black on the range hood to the Blue on the motor (Neutral) and the earth to the earth (Green).
Disconnect and toss the cap in the white enclosure under the PC board enclosure (the new fan has the cap on board). Don't know how easy to fit in the range hood as mine is in an acoustic fan housing in the roof (makes it wisper quiet when running)
769 views