Black Imaging Unit failure
• All density readings taken from the density pattern produced
on the Transfer Belt are 0.5 g/m2 (IDC Sensor
photoreceiver output) or less during max. density
adjustment (Vg/Vdc adjustment).
• All density readings taken from the density pattern produced
on the Transfer Belt are 4.5 g/m2 (IDC Sensor
Photoreceiver output) or more during max. density
adjustment (Vg/Vdc adjustment.)
Remove and reset the Black Image Unit. If this doesn't help the Image Unit may need to be replaced.
How can I run image quality adjustment on bizhub c351
870 views
Usually answered in minutes!
×