Fahrenheat (FFH1614) Wall Mounted Panel Heater Logo

Related Topics:

Posted on Apr 23, 2010
Answered by a Fixya Expert

Trustworthy Expert Solutions

At Fixya.com, our trusted experts are meticulously vetted and possess extensive experience in their respective fields. Backed by a community of knowledgeable professionals, our platform ensures that the solutions provided are thoroughly researched and validated.

View Our Top Experts

I have a fahrenheat wall mounted heater, 120 v model,(can't find a model number on the unit) with a dial temp control. No matter which number setting it is on, the unit cycles off after about 50 seconds. It heats, the fan blows, but it doesn't stay on. An amber light comes on when it shuts off. After about 5 minutes it will cycle on again but for less than 1 min. It didn't do this when I installed it new, which was in 1994 or 95. What's the problem

1 Answer

Anonymous

Level 2:

An expert who has achieved level 2 by getting 100 points

MVP:

An expert that got 5 achievements.

Governor:

An expert whose answer got voted for 20 times.

New Friend:

An expert that has 1 follower.

  • Expert 59 Answers
  • Posted on Apr 24, 2010
Anonymous
Expert
Level 2:

An expert who has achieved level 2 by getting 100 points

MVP:

An expert that got 5 achievements.

Governor:

An expert whose answer got voted for 20 times.

New Friend:

An expert that has 1 follower.

Joined: Apr 20, 2010
Answers
59
Questions
0
Helped
30390
Points
119

UNIT SOUNDS LIKE ITS SHUTTING DOWN ON A LIMIT SWITCH IN HEATER. THEY LOOK LIKE ROUND BUTTONS OF DIFFERENT SIZES. THE HAVE 2 WIRES GOING TO THEM AND THEY ARE A NORMALLY CLOSED. THERE IS A FAN DISK NORMALLY OPEN TO UNTILL IT GETS HOT AND CLOSES TO TURN ON FAN.  IF THE FAN SWITCH TAKES TO LONG TO CLOSE THEN LIMIT OPENS TO PROTECT FROM OVER-HEATING

Add Your Answer

×

Uploading: 0%

my-video-file.mp4

Complete. Click "Add" to insert your video. Add

×

Loading...
Loading...

Related Questions:

0helpful
1answer

How to wire a honeywell ct410b 4 pole thermostat to a fahrenheater model fuh724 ceiling heater.

Similar Options to ConsiderSee All

Cadet Double-Pole 22 Amp 120/240-Volt Wall-Mount Mechanical Non-programmable Thermostat in Almond
(26)
$3217/each
Cadet Double-Pole Electric Baseboard-Mount Mechanical Thermostat in White
(84)
$2498/each
Economy Heat/Cool Manual Thermostat
(128)
$1888/each
Wireless PTAC Wall Remote Thermostat
(0)
$18482/package
tekmar Radiant 519 - Digital Non-Programmable 1-Stage Heat Thermostat with Slab Sensor 079
(3)
$11563/each
White RodgersB30 Baseboard Non-Programmable Thermostat - Single Pole
(1)
$1256/each
Broan Cold Weather Non-Programmable Solar Power Attic Vent Thermostat
(0)
$986/each
Was $24.66
Fahrenheat Non-Programmable Wall-Mount Thermostat
(18)
$2074/each
White RodgersB50 Baseboard Non-Programmable Thermostat - Dual Pole
(6)
$1999/each
Cadet Single-Pole Electric Baseboard-Mount Mechanical Thermostat in White
(42)
$2198/each
Cadet Double Pole 15 Amp 208/240-Volt Digital Electronic Non-Programmable Wall Thermostat in White
(72)
$5808/each
Model # CT410B Internet #100574426 Store SKU #129002
Honeywell Manual Electric Baseboard Thermostat (123)
Questions & Answers (32)
  • Manual 4 Wire Premium Baseboard/Line Volt Thermostat
  • Compatible with 120, 240 and 277 vac baseboard heat systems
  • Simple dial-type mechanical control


Quantity -
+ store iconPick Up In Store
Unavailable at Guam - Tamuning
Check Nearby Stores package iconWe'll Deliver It to You
UnavailableDelivery is unavailable for this product Your local store: Guam - Tamuning
Store Details & Services Accessories (1) Product Overview
The easy-to-install Honeywell Manual Electric Baseboard Thermostat works on 4-wire (double pole) electric heat applications (baseboard or line volt) and allows for simple, worry-free operation. It has a simple dial-type mechanical control and is UL and CSA listed for safety.

Info & Guides

You will need Adobe® Acrobat® Reader to view PDF documents. Download a free copy from the Adobe Web site.
Compare Similar Non-Programmable Thermostats
Price $21.99/each $24.97/each $44.28/each null¢ /null Name Double Pole 4-Wire Line Voltage Mechanical Thermostat Digital Non-Programmable Thermostat Single-Pole 10.4 Amp 120/240-Volt Digital Electronic Non-Programmable Wall Thermostat in White Manual Electric Baseboard Thermostat Brand Lux Honeywell Cadet Honeywell Ratings View Product View Product View Product View Product Specifications
Dimensions
Product Depth (in.)
1.5
Product Height (in.)
4.5
Product Width (in.)
2.75

Details
Color Family
Whites
Color Family
White
Operation Type
Mechanical
Returnable
90-Day
Shape
Rectangle
Thermostat Product Type
Non-Programmable Thermostat
Thermostat Shape
Rectangular
Thermostat Type
Heat Only
Voltage (v)
110/240v
Voltage (volts)
110/240
Warranty / Certifications
Certifications and Listings
1-UL Listed,CSA Listed
Manufacturer Warranty
1 year limited warranty
How can we improve our product information? Provide feedback.
0helpful
1answer

Fahrenheat ffh1614 wall heater gets bright orange and way too hot

You need to check the breakers or the actual power because I see the 1614 model as being 240 Volts. Unless you can change that rating inside the unit itself and it has been set to 120 Volts. IT appears from the wiring code you listed that the building wires are 120 volts. However a meter would be the definitive answer. When you are running 240 or higher (double phase) Black and Red are hot and white is neutral If it is 110 then black is hot and white is neutral. Since I cannot tell from the description posted whether the red is source or inside the heater, you really need a volt meter.
0helpful
1answer

How to wire unit baseboard heater to the power to thermoster

That is a portable unit and should not be hard-wired and controlled by a wall-mounted thermostat. The unit may never cut off that way.

It is considered a "space heater" not an area heater.

===sorry===

0helpful
1answer

Thermostat for Fahrenheat 5000Watt Ceiling mount heater

You could do it. It would mean serious wiring though and you should use the factory thermostat because it is designed to operate on 240 Volts. Or you could use a remote thermostat at low voltage to throw a relay in the heater and get it to come on. The manual has good diagrams on how it is wired and it would not be too hard to do. IT would operate just like the outside unit on an HVAC system .
0helpful
2answers

Installation of Fahrenheat wall heater

http://www.marleymeh.com/develop/prod_pdf/instructs/5200-2638-000.pdf
0helpful
1answer

Can someone please tell me what is the lowest temperature setting a Fahrenheat 3000 Watt Large Room Fan-Forced Wall Heater Model FZL3004 will turn on at ?

about the only way I can figure is to let the room get very cool and adjust the thermostat to its lowest setting. now turn on the unit. monitor the heat until the stat just opens. the thermostat bimetal will be closed and will open when the bimetal expands and opens its contacts. another way is to hitch up a chart recorder to measure temperature with its output connected to the heater. [too expensive for you or the DIY to accomplish]
0helpful
1answer

Fahrenheat wall unit

your on-off switch is faulty - need to replace it.
1helpful
2answers

Fahrenheat 4000 watt wall mounted heater shuts off and needs reset

the reset is probably an inline circuit breaker. if you can get hold of am amprobe clamp around ammeter, check the current when the unit is running at full power. the reading you get check against the current rating of the inline breaker. your fan motor bearings may be dry increasing the current draw of the unit and tripping the breaker. try oiling the fan bearings with a light oil NOT WD-40.
Not finding what you are looking for?

337 views

Ask a Question

Usually answered in minutes!

Top Fahrenheat Heating & Cooling Experts

Paul Carew

Level 3 Expert

3808 Answers

Brad Brown

Level 3 Expert

19187 Answers

Paul Katynski
Paul Katynski

Level 3 Expert

575 Answers

Are you a Fahrenheat Heating and Cooling Expert? Answer questions, earn points and help others

Answer questions

Manuals & User Guides