You should check the heat sensor and oil sensor.by ifesi
Low frequency means the RPM of the motor has fallen off.
Check your fuel is NOT contaminated or fuel filters plugged.
Further tests should focus on the govenor system. Possibly it fails when engine gets hot. the frequency is directly proportional to the engine speed.
Please check the connector with six wires, closer to diesel injection pump. There will be loose connection in the connector.
Frequency is one of the criteria for the stability of power supply. If the frequency of generator set varies greatly, it will cause damage to electrical equipment and lead to machine failure or safety accident. Therefore, generators set/Perkins generator should be maintained at rated frequencies as far as possible.
After the diesel generator is started, the generator generates electricity, but the frequency of generation is only up to 45 Hz.
Fault analysis:
This kind of fault appears to be a fault inside the generator or the control part of the generator, but in fact it is caused by the diesel engine fuel supply system or the mechanical failure of the diesel engine that the diesel engine speed does not reach the rated speed, resulting in the generation frequency of less than 50 Hz.
Cause of failure:
1. Diesel engines have individual cylinders that work poorly or not.
2. Low pressure partial blockage.
3. The quantity of oil supplied by the high pressure oil pump does not meet the requirements of the machine or the internal plunger of the high pressure oil pump is jammed.
4. There is air in the oil path.
5. The overhaul of the connecting rod bolts of the diesel engine is too strong, causing the connecting rod bush to be too tight with the journal.
6. Poor work of oil pump.
7. Individual injectors do not inject oil.
More information at this article: https://www.dieselgeneratortech.com/generator-sets/Low-Frequency-of-Diesel-Generator-Set.html